Dell Latitude Xpi CD MMX Service Manual - Page 32
Table 3-2., System Error Messages, Disk C: failed
View all Dell Latitude Xpi CD MMX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Table 3-2. System Error Messages (Continued) Message Definition Probable Causes Decreasing available memory Informational message indicating memory is failing (usually preceded by memory error message). One or more DIMMs faulty or improperly seated. Disk C: failed initialization Hard-disk drive failed to initialize. Hard-disk drive data in System Setup does not match installed hard-disk drive, or hard-disk drive faulty. Diskette drive 0 System cannot read dis- seek failure kette in diskette drive. Diskette read failure System files missing or corrupted. Diskette faulty or incorrectly inserted in drive. System Setup contains incorrect settings. Diskette drive interface loose or faulty. Diskette subsystem reset failed Diskette writeprotected Drive not ready Error reading PCMCIA card Diskette subsystem failed to respond to reset command from computer. Diskette is writeprotected, operation cannot be completed. The diskette may be missing from or improperly installed in the diskette drive. Computer cannot identify PC Card. Diskette drive faulty. System board faulty. Diskette writeprotected. Defective or unformatted diskette. PC Card faulty, improperly seated, or improperly configured. System board faulty. PC Card software faulty or incorrectly installed. 3-4 Dell Latitude XPi CD Service Manual