Dell PowerConnect Brocade M6505 Quick Start Guide - Page 6

Using the CMC GUI to set the IP address

Page 6 highlights

Using the CMC GUI to set the IP address To modify the SAN I/O Module IP address using the CMC GUI, perform the following steps: 1. Select I/O Module Overview from the left navigation panel. 2. Click the Setup tab. 3. Enter the new information in the IP Address, Subnet Mask, and Gateway fields as appropriate, then click Apply. 4. To enable DHCP, select DHCP Enabled, then click Apply. Refer to the Dell PowerEdge M1000e Enclosure Owner's Manual that comes with your Dell M1000e Blade Server Enclosure for more information. Using the CMC CLI to set the IP address To modify the SAN I/O Module IP address through the Chassis Management Controller (CMC) CLI, perform the following steps: 1. Establish a Telnet session to the CMC CLI. 2. At the command prompt, enter connect switch-x where x is the bay in which the SAN I/O Module is installed. For example, switch-x can be one of the following values: • Switch-3 for SAN I/O Module installed in bay B1. • Switch-4 for SAN I/O Module installed in bay B2. • Switch-5 for SAN I/O Module installed in bay C1. • Switch-6 for SAN I/O Module installed in bay C2. 3. Log in to the default administrative account using the following default settings: Login: admin Password: password 4 Brocade M6505 16 Gbps Fibre Channel SAN I/O Module QuickStart Guide 53-1002577-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

4
Brocade M6505 16 Gbps Fibre Channel SAN I/O Module QuickStart Guide
53-1002577-01
Using the CMC GUI to set the IP address
To modify the SAN I/O Module IP address using the CMC GUI, perform the following steps:
1.
Select
I/O Module Overview
from the left navigation panel.
2.
Click the
Setup
tab.
3.
Enter the new information in the
IP Address
,
Subnet Mask
, and
Gateway
fields as appropriate,
then click
Apply
.
4.
To enable DHCP, select
DHCP Enabled
, then click
Apply
.
Refer to the
Dell PowerEdge M1000e Enclosure Owner’s Manual
that comes with your Dell
M1000e Blade Server Enclosure for more information.
Using the CMC CLI to set the IP address
To modify the SAN I/O Module IP address through the Chassis Management Controller (CMC) CLI,
perform the following steps:
1.
Establish a Telnet session to the CMC CLI.
2.
At the command prompt, enter
connect switch-x
where
x
is the bay in which the SAN I/O
Module is installed. For example,
switch-x
can be one of the following values:
Switch-3
for SAN I/O Module installed in bay B1.
Switch-4
for SAN I/O Module installed in bay B2.
Switch-5
for SAN I/O Module installed in bay C1.
Switch-6
for SAN I/O Module installed in bay C2.
3.
Log in to the default administrative account using the following default settings:
Login:
admin
Password:
password