Dell PowerEdge MX7000 EMC OpenManage Enterprise Modular Edition Version 1.20.0 - Page 13

config, connect - blade chassis

Page 13 highlights

NOTE: During a failover, the chassis power state on the OME - Modular GUI is displayed as "off". The original power state is displayed after the inventory is refreshed. config Description Synopsis Modifies the configuration properties of the management module. NOTE: Use racadm config command to set basic attributes such as IP address attributes, to access the system. To configure complex or multiple networking attributes such as DNS registration attributes use the RESTful API or OME-Modular web interface. The racadm interface does not facilitate setting multiple dependent attributes in a single call. racadm config -g -o [-m ] Input Example racadm config -g -i -o • -g-Configuration group to which the object belongs • -o-Configuration object to configure • -i-Index of indexed group, which is used with -g and -o • -m-The module must have one of the following values: - storage-- where n=1 to 8 NOTE: The storage - option is available only for cfgStorageModule • -Value of the configuration object • Configure a single property of a group: racadm config -g cfgLanNetworking -o cfgDNSRacName NAME • Configure a single property of a group for a particular user: racadm config -g cfgUserAdmin -i 2 -o cfgUserAdminPassword PASSWORD connect Description Synopsis Connects to switch or blade serial console. The connect command is supported only on firmware interfaces. NOTE: To terminate racadm connect command, use control+\(backslash). NOTE: You can connect eight serial sessions simultaneously for compute sleds using racadm connect command. racadm connect [-b] -m Input • -b-Binary mode If -b is used, reset OME-Modular to terminate the connect. • -m-The option must be one of the following values: ○ server--where n = 1-8 ○ switch--where n = 1-6 CAUTION: When run from the OME-Modular serial console, the connect -b option stays connected until the management module resets or the serial console is terminated. This connection is a potential security risk. NOTE: The racadm connect to server prompts you to enter the iDRAC credentials for connecting to the server. RACADM sub command details 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

NOTE:
During a failover, the chassis power state on the OME - Modular GUI is displayed as "off". The original power
state is displayed after the inventory is refreshed.
config
Description
Modifies the configuration properties of the management module.
NOTE:
Use
racadm config
command to set basic attributes such as IP address attributes, to
access the system. To configure complex or multiple networking attributes such as DNS
registration attributes use the RESTful API or OME-Modular web interface. The racadm interface
does not facilitate setting multiple dependent attributes in a single call.
Synopsis
racadm config -g <group> -o <object> <value> [-m <module>]
racadm config -g <group> -i <index> -o <object> <value>
Input
-g
—Configuration group to which the object belongs
-o
—Configuration object to configure
-i
—Index of indexed group, which is used with
-g
and
-o
-m
—The
module
must have one of the following values:
- storage-<n>-
where n=1 to 8
NOTE:
The storage -<n> option is available only for
cfgStorageModule
<value>
—Value of the configuration object
Example
Configure a single property of a group:
racadm config -g cfgLanNetworking -o cfgDNSRacName NAME
Configure a single property of a group for a particular user:
racadm config -g cfgUserAdmin -i 2 -o cfgUserAdminPassword PASSWORD
connect
Description
Connects to switch or blade serial console. The
connect
command is supported only on firmware interfaces.
NOTE:
To terminate
racadm connect
command, use control+\(backslash).
NOTE:
You can connect eight serial sessions simultaneously for compute sleds using
racadm
connect
command.
Synopsis
racadm connect [-b] -m <module>
Input
-b
—Binary mode
If
-b
is used, reset OME-Modular to terminate the
connect
.
-m
—The
<module>
option must be one of the following values:
server-<n>
—where n = 1-8
switch-<n>
—where n = 1-6
CAUTION:
When run from the OME–Modular serial console, the
connect -b
option stays
connected until the management module resets or the serial console is terminated. This
connection is a potential security risk.
NOTE:
The
racadm connect
to server prompts you to enter the iDRAC credentials for connecting
to the server.
RACADM sub command details