Dell PowerEdge MX7000 EMC OpenManage Enterprise Modular Edition Version 1.20.0 - Page 17

getmodinfo, getniccfg, getpbinfo

Page 17 highlights

• Display all available configuration groups: racadm getconfig -h getmodinfo Description Synopsis Gets module configuration and status information. NOTE: If the Power Supply Unit (PSU) is absent, the RACADM interface displays the health state and power status for the PSU as N/A. racadm getmodinfo [-m ] Input Example -m-The must have one of the following values: • server--Where n = 1 to 8 • switch--Where n = 1 to 6 • mm- -Where n = 1, 2 • fan--Where n = 1 to 9 • ps- -Where n = 1 to 6 • storage--chassis • Display rollup status of all the modules in the chassis. racadm getmodinfo • Display status of fan module 3 in the chassis. racadm getmodinfo -m fan-3 getniccfg Description Synopsis Displays the network settings for modules. racadm getniccfg [-m ] Input Example -m-The must be one of the following values: • chassis-Default state if -m is not specified. • switch--Where n = 1-6 • Display switch network settings racadm getniccfg -m switch-1 • Display chassis network settings racadm getniccfg -m chassis getpbinfo Description Gets power budget status information. If there is no power supply to the PSU, the output of the command is displayed as Input Lost. If there is a mismatch in the power source, for example, a PSU of 220 Volts and PSU of 110 Volts are combined, then the output of the command is displayed as Configuration Error. RACADM sub command details 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

Display all available configuration groups:
racadm getconfig -h
getmodinfo
Description
Gets module configuration and status information.
NOTE:
If the Power Supply Unit (PSU) is absent, the RACADM interface displays the health state
and power status for the PSU as
N/A
.
Synopsis
racadm getmodinfo [-m <module>]
Input
-m
—The
<module>
must have one of the following values:
server-<n>
—Where n = 1 to 8
switch-<n>
—Where n = 1 to 6
mm-<n>
—Where n = 1, 2
fan-<n>
—Where n = 1 to 9
ps-<n>
—Where n = 1 to 6
storage-<n>
—chassis
Example
Display rollup status of all the modules in the chassis.
racadm getmodinfo
Display status of fan module 3 in the chassis.
racadm getmodinfo -m fan-3
getniccfg
Description
Displays the network settings for modules.
Synopsis
racadm getniccfg [-m <module>]
Input
-m
—The
<module>
must be one of the following values:
chassis
—Default state if -m is not specified.
switch-<n>
—Where n = 1–6
Example
Display switch network settings
racadm getniccfg -m switch-1
Display chassis network settings
racadm getniccfg -m chassis
getpbinfo
Description
Gets power budget status information. If there is no power supply to the PSU, the output of the command is
displayed as
Input Lost
. If there is a mismatch in the power source, for example, a PSU of 220 Volts and PSU of
110 Volts are combined, then the output of the command is displayed as
Configuration Error
.
RACADM sub command details