Dell PowerEdge MX7000 EMC OpenManage Enterprise Modular Edition Version 1.20.0 - Page 29
cfgStorageModule, cfgStorageModuleStorageMode, cfgStorageModuleServiceTag
View all Dell PowerEdge MX7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
• NIC Enabled • IPv6 Enabled • Autoconfiguration Enabled The network administrator must ensure that these DHCP servers are configured to provide the same DNS domain name to the management module. Else, the domain name becomes unpredictable. cfgStorageModule Description Synopsis Input Example This command is used only with the getconfig command. • cfgStorageModuleStorageMode= • # cfgStorageModuleServiceTag= • cfgStorageModuleAssetTag= • cfgConnectedSlots= • cfgStorageModuleStorageMode=2 • # cfgStorageModuleServiceTag=MX0000 • cfgStorageModuleAssetTag= • cfgConnectedSlots=2,2,2,2,2,2,2,2 cfgStorageModuleStorageMode Description Displays the storage module. Synopsis cfgStorageModuleStorageMode= Input Example cfgStorageModuleStorageMode= NOTE: • If the storage mode is 1, then cfgConnectedSlots will be list of all connected slots to that particular enclosure. • If the storage mode is 2, then cfgConnectedSlots shows the assignment for each drive. cfgStorageModuleStorageMode=2 cfgStorageModuleServiceTag Description Displays the service tag. OpenManage Enterprise Modular property database group and object descriptions 29