Dell PowerEdge R830 Lifecycle Controller GUI v2.30.30.30 Users Guide - Page 38

Selecting the type of update and update source, Apply, View Current, Versions, Firmware Update

Page 38 highlights

7. Select the components that require an update, and then click Apply. The update process is initiated and the firmware update is completed. After restart, the system is ready to use. NOTE: The system does not restart if operating system driver packs, OS collector tool, or hardware diagnostics are updated. NOTE: When applying more than one update, the system may restart between updates. In this case, Lifecycle Controller restarts the server and automatically continues the update process. NOTE: iDRAC resets while updating iDRAC. If the iDRAC firmware update is interrupted for any reason, wait for up to 30 minutes before you attempt another firmware update. NOTE: After the CPLD firmware is updated on the modular servers, on the View Current Versions page, under Firmware Update, the firmware update date is displayed as 2000-01-01, regardless of the actual update date. The updated date and time are displayed based on the time zone that is configured on the server. NOTE: On a Dell PowerEdge server, if you use Lifecycle Controller to update the Intel Network Card firmware from version 15.0.xx to 16.5.xx or vice versa, reboot the server to view the updated firmware. NOTE: If you update the Intel Network Card firmware from version 14.5.x to 16.5.xx or vice versa on a Dell PowerEdge server by using Lifecycle Controller, the Firmware Rollback page may display the firmware version as 15.0.xx instead of 14.5.x . However, the Firmware Rollback page displays the version 14.5.x if you update the firmware by using the Intel Network firmware DUPs on the OS. Related Links Firmware update Firmware update methods Version compatibility Selecting the type of update and update source Selecting and applying updates Updating or rolling back devices that affect Trusted Platform Module settings Selecting the type of update and update source To perform the updates, you can download single component DUPs or repository (Catalog.xml) using the Firmware Update wizard to one of the following: NOTE: The Catalog.xml file contains the individual server bundles. Each bundle consists of all the DUP information (md5 security key, date and time, path, Release ID, version, and so on). • FTP server - Dell FTP Server, Local FTP, or FTP server using a proxy server. NOTE: Make sure that the repository (catalog file) and DUPs are copied to the root folder of the source • Local Drive - Use a USB drive, Dell Server Updates DVD, or Lifecycle Controller OS Driver Packs DVD • Network Share (CIFS, NFS, and HTTP) Related Links Comparing firmware versions Using single component DUPs Using a local drive Using a FTP server 38

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

7.
Select the components that require an update, and then click
Apply
.
The update process is initiated and the firmware update is completed. After restart, the system is
ready to use.
NOTE:
The system does not restart if operating system driver packs, OS collector tool, or
hardware diagnostics are updated.
NOTE:
When applying more than one update, the system may restart between updates. In this
case, Lifecycle Controller restarts the server and automatically continues the update process.
NOTE:
iDRAC resets while updating iDRAC. If the iDRAC firmware update is interrupted for any
reason, wait for up to 30 minutes before you attempt another firmware update.
NOTE:
After the CPLD firmware is updated on the modular servers, on the
View Current
Versions
page, under
Firmware Update
, the firmware update date is displayed as 2000-01-01,
regardless of the actual update date. The updated date and time are displayed based on the
time zone that is configured on the server.
NOTE:
On a Dell PowerEdge server, if you use Lifecycle Controller to update the Intel Network
Card firmware from version 15.0
.xx
to 16.5
.xx
or vice versa, reboot the server to view the
updated firmware.
NOTE:
If you update the Intel Network Card firmware from version 14.5
.x
to 16.5
.xx
or vice
versa on a Dell PowerEdge server by using Lifecycle Controller, the
Firmware Rollback
page
may display the firmware version as 15.0
.xx
instead of 14.5
.x
. However, the
Firmware Rollback
page displays the version 14.5.x if you update the firmware by using the Intel Network firmware
DUPs on the OS.
Related Links
Firmware update
Firmware update methods
Version compatibility
Selecting the type of update and update source
Selecting and applying updates
Updating or rolling back devices that affect Trusted Platform Module settings
Selecting the type of update and update source
To perform the updates, you can download single component DUPs or repository (
Catalog.xml
) using
the
Firmware Update
wizard to one of the following:
NOTE:
The
Catalog.xml
file contains the individual server bundles. Each bundle consists of all the
DUP information (md5 security key, date and time, path, Release ID, version, and so on).
FTP server — Dell FTP Server, Local FTP, or FTP server using a proxy server.
NOTE:
Make sure that the repository (catalog file) and DUPs are copied to the root folder of the
source
Local Drive — Use a USB drive,
Dell Server Updates
DVD, or
Lifecycle Controller OS Driver Packs
DVD
Network Share (CIFS, NFS, and HTTP)
Related Links
Comparing firmware versions
Using single component DUPs
Using a local drive
Using a FTP server
38