Dell PowerEdge SDS 100 Dell PowerEdge R720 and R720xd Owner's Manual - Page 148
LCD Message, Message Information
View all Dell PowerEdge SDS 100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 148 highlights
Error Code AMP0302 AMP0303 ASR0000 ASR0001 ASR0002 Message Information Message Details Action The system board current is greater than the upper warning threshold. System board current is outside of the optimum range. 1. Review system power policy. 2. Check system logs for power related failures. 3. Review system configuration changes. 4. If the issue persists, see Getting Help. Message LCD Message Details Action The system board current is greater than the upper critical threshold. System board current is outside of range. System board current is outside of the optimum range. 1. Review system power policy. 2. Check system logs for power related failures. 3. Review system configuration changes. 4. If the issue persists, see Getting Help. Message Details Action Message Details Action Message Details Action The watchdog timer expired. The operating system or an application failed to communicate within the time-out period. Check the operating system, application, hardware, and system event log for exception events. The watchdog timer reset the system. The operating system or an application failed to communicate within the time-out period. The system was reset. Check the operating system, application, hardware, and system event log for exception events. The watchdog timer powered off the system. The operating system or an application failed to communicate within the time-out period. The system was shut down. Check the operating system, application, hardware, and system event log for exception events. 148