Dell PowerStore 3200T EMC PowerStore Alerts and Events Reference Guide - Page 104

Ensure Fail-Safe Network

Page 104 highlights

Alert and Event Messages Event code Severity Alert raised 0x01807B05 MAJOR TRUE 0x01A00201 INFO FALSE 0x01A00202 CRITICAL TRUE 0x01A00401 INFO FALSE Call home FALSE FALSE TRUE FALSE Message All ports of the Fail-Safe Network (FSN) are in link down state. Management operations are enabled. Management operations are disabled. Non-essential database functions are operating normally. Repair flow Ensure Fail-Safe Network (FSN) ports are properly cabled and data switch ports are up. System impact Network connectivity is limited. Knowledge Base Article https://dell.com/support/kbdoc/00 0197305 - - - Contact your service provider for assistance. Cluster management is unavailable. https://dell.com/support/kbdoc/00 0132219 - - - 0x01A00402 CRITICAL TRUE TRUE Metrics collection and other nonessential database activities are disabled due to space issues. Contact your service provider for assistance. Metrics collection and other nonessential database activities are disabled. https://dell.com/support/kbdoc/00 0128499 0x01A00501 INFO 0x01A00502 MAJOR 0x01B00101 MAJOR FALSE FALSE The internal metrics database volume is operating normally. TRUE TRUE An internal metrics database volume is faulted. TRUE FALSE Refreshing the volume group %(volume_group_name) failed. - - - Contact your service provider for assistance. Restore the volume group from the backup snapshot (%(backup_snapset_nam e)). If an error caused the refresh to fail, resolve the error and try refreshing again. Metrics collection is disabled across the cluster until the fault is cleared. - Gaps in metrics will remain even after the fault is cleared. The data across all the volumes in the group may not be consistent. https://dell.com/support/kbdoc/00 0179617 If the error persists contact support. 0x01B00102 INFO FALSE FALSE The volume group %(volume_group_name) was refreshed successfully. - - - 104 Dell EMC PowerStore Events and Alerts Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Alert and Event Messages
104
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert
raised
Call
home
Message
Repair flow
System impact
Knowledge Base Article
0x01807B05
MAJOR
TRUE
FALSE
All ports of the Fail-Safe Network
(FSN) are in link down state.
Ensure Fail-Safe Network
(FSN) ports are properly
cabled and data switch
ports are up.
Network
connectivity is
limited.
https://dell.com/support/kbdoc/00
0197305
0x01A00201
INFO
FALSE
FALSE
Management operations are
enabled.
-
-
-
0x01A00202
CRITICAL
TRUE
TRUE
Management operations are
disabled.
Contact your service
provider for assistance.
Cluster
management is
unavailable.
https://dell.com/support/kbdoc/00
0132219
0x01A00401
INFO
FALSE
FALSE
Non-essential database functions
are operating normally.
-
-
-
0x01A00402
CRITICAL
TRUE
TRUE
Metrics collection and other non-
essential database activities are
disabled due to space issues.
Contact your service
provider for assistance.
Metrics collection
and other non-
essential database
activities are
disabled.
https://dell.com/support/kbdoc/00
0128499
0x01A00501
INFO
FALSE
FALSE
The internal metrics database
volume is operating normally.
-
-
-
0x01A00502
MAJOR
TRUE
TRUE
An internal metrics database
volume is faulted.
Contact your service
provider for assistance.
Metrics collection is
disabled across the
cluster until the
fault is cleared.
Gaps in metrics will
remain even after
the fault is cleared.
-
0x01B00101
MAJOR
TRUE
FALSE
Refreshing the volume group
%(volume_group_name) failed.
Restore the volume group
from the backup snapshot
(%(backup_snapset_nam
e)).
If an error caused the
refresh to fail, resolve the
error and try refreshing
again.
If the error persists contact
support.
The data across all
the volumes in the
group may not be
consistent.
https://dell.com/support/kbdoc/00
0179617
0x01B00102
INFO
FALSE
FALSE
The volume group
%(volume_group_name) was
refreshed successfully.
-
-
-