Dell PowerStore 3200T EMC PowerStore Alerts and Events Reference Guide - Page 16

Con authentication

Page 16 highlights

Alert and Event Messages Event code Severity Alert raised Call home Message 0x00301604 INFO FALSE FALSE The drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has changed from %(old_value) to %(tcg_compliance). Repair flow System impact Knowledge Base Article - - - 0x00301701 MINOR 0x00301702 INFO 0x00301703 INFO 0x00301704 MAJOR 0x00301C01 MINOR 0x00301D02 MINOR FALSE FALSE FALSE FALSE FALSE FALSE The drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has changed from %(old_value) to %(fips_status). The drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has changed from %(old_value) to %(fips_status). The drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) has changed from %(old_value) to %(fips_status). - - - - - - - - - TRUE TRUE TRUE FALSE The drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) does not meet FIPS requirements. TRUE Mutual CHAP is enabled, but not configured for some initiators. TRUE CHAP is enabled, but not configured for some initiators. Replace the drive. Refer to the Installation and Service Guide for more information. Configure authentication credentials for the initiators. Otherwise, a failure will occur when an initiator is disconnected and then re-connected. Configure authentication credentials for the initiators. Otherwise, a failure will occur when an initiator is disconnected and then re-connected. The drive is not usable. Initiator is not available until credentials are assigned. Initiator is not available until credentials are assigned. https://dell.com/support/kbdoc/00 0124918 https://dell.com/support/kbdoc/00 0125540 https://dell.com/support/kbdoc/00 0125540 0x00302902 MINOR FALSE FALSE Node's health state has changed. - - - 16 Dell EMC PowerStore Events and Alerts Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Alert and Event Messages
16
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert
raised
Call
home
Message
Repair flow
System impact
Knowledge Base Article
0x00301604
INFO
FALSE
FALSE
The drive in bus %(bus_num)
enclosure %(encl_num) slot
%(enclosure_slot) has changed
from %(old_value) to
%(tcg_compliance).
-
-
-
0x00301701
MINOR
FALSE
FALSE
The drive in bus %(bus_num)
enclosure %(encl_num) slot
%(enclosure_slot) has changed
from %(old_value) to
%(fips_status).
-
-
-
0x00301702
INFO
FALSE
FALSE
The drive in bus %(bus_num)
enclosure %(encl_num) slot
%(enclosure_slot) has changed
from %(old_value) to
%(fips_status).
-
-
-
0x00301703
INFO
FALSE
FALSE
The drive in bus %(bus_num)
enclosure %(encl_num) slot
%(enclosure_slot) has changed
from %(old_value) to
%(fips_status).
-
-
-
0x00301704
MAJOR
TRUE
FALSE
The drive in bus %(bus_num)
enclosure %(encl_num) slot
%(enclosure_slot) does not meet
FIPS requirements.
Replace the drive. Refer
to the Installation and
Service Guide for more
information.
The drive is not
usable.
https://dell.com/support/kbdoc/00
0124918
0x00301C01
MINOR
TRUE
TRUE
Mutual CHAP is enabled, but not
configured for some initiators.
Configure authentication
credentials for the
initiators. Otherwise, a
failure will occur when an
initiator is disconnected
and then re-connected.
Initiator is not
available until
credentials are
assigned.
https://dell.com/support/kbdoc/00
0125540
0x00301D02
MINOR
TRUE
TRUE
CHAP is enabled, but not
configured for some initiators.
Configure authentication
credentials for the
initiators. Otherwise, a
failure will occur when an
initiator is disconnected
and then re-connected.
Initiator is not
available until
credentials are
assigned.
https://dell.com/support/kbdoc/00
0125540
0x00302902
MINOR
FALSE
FALSE
Node's health state has changed.
-
-
-