Alert and Event Messages Event code Severity Alert raised Call home Message 0x00308602 INFO FALSE FALSE Expansion enclosure power supply input state has changed. Repair flow System impact Knowledge Base Article - - - 0x00308701 INFO FALSE FALSE Expansion enclosure power supply state has changed. - - - 0x00308901 INFO FALSE FALSE Expansion enclosure power supply lifecycle state has changed. - - - 0x00308902 MINOR FALSE FALSE The bus %(bus_num) enclosure %(encl_num) %(location) power supply is initializing. - - - 0x00308B01 INFO FALSE FALSE Expansion enclosure lifecycle state has changed. - - - 0x00308B02 MINOR 0x00308B03 MAJOR 0x00308B04 MAJOR FALSE TRUE TRUE FALSE TRUE TRUE Expansion enclosure %(encl_num) at bus %(bus_num) is initializing. Expansion enclosure %(encl_num) at bus %(bus_num) has faulted. Expansion enclosure %(encl_num) at bus %(bus_num) is disconnected. - - - Check for hardwarerelated alerts and take appropriate action. If the issue persists, contact your service provider. Check your cables and connections. Try reconnecting the expansion enclosure. If the issue persists, contact your service provider. Data availability and performance may be degraded. Performance may be degraded. https://dell.com/support/kbdoc/00 0130344 https://dell.com/support/kbdoc/00 0130344 24 Dell EMC PowerStore Events and Alerts Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Alert and Event Messages
24
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert
raised
Call
home
Message
Repair flow
System impact
Knowledge Base Article
0x00308602
INFO
FALSE
FALSE
Expansion enclosure power
supply input state has changed.
-
-
-
0x00308701
INFO
FALSE
FALSE
Expansion enclosure power
supply state has changed.
-
-
-
0x00308901
INFO
FALSE
FALSE
Expansion enclosure power
supply lifecycle state has
changed.
-
-
-
0x00308902
MINOR
FALSE
FALSE
The bus %(bus_num) enclosure
%(encl_num) %(location) power
supply is initializing.
-
-
-
0x00308B01
INFO
FALSE
FALSE
Expansion enclosure lifecycle
state has changed.
-
-
-
0x00308B02
MINOR
FALSE
FALSE
Expansion enclosure
%(encl_num) at bus %(bus_num)
is initializing.
-
-
-
0x00308B03
MAJOR
TRUE
TRUE
Expansion enclosure
%(encl_num) at bus %(bus_num)
has faulted.
Check for hardware-
related alerts and take
appropriate action. If the
issue persists, contact
your service provider.
Data availability
and performance
may be degraded.
https://dell.com/support/kbdoc/00
0130344
0x00308B04
MAJOR
TRUE
TRUE
Expansion enclosure
%(encl_num) at bus %(bus_num)
is disconnected.
Check your cables and
connections. Try
reconnecting the
expansion enclosure. If
the issue persists, contact
your service provider.
Performance may
be degraded.
https://dell.com/support/kbdoc/00