Dell PowerStore 3200T EMC PowerStore Alerts and Events Reference Guide - Page 31

Base Enclosure's LED is blinking.

Page 31 highlights

Alert and Event Messages Event code Severity Alert raised 0x0030AF06 MAJOR TRUE Call home Message TRUE Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down because one or more required hardware components are not installed. Repair flow Check for hardwarerelated alerts and take appropriate action. If the issue persists, contact your service provider. System impact Knowledge Base Article Data availability and performance may be degraded. https://dell.com/support/kbdoc/00 0130344 0x0030AF07 MAJOR 0x0030B001 INFO 0x0030B003 INFO 0x0030B004 INFO 0x0030B103 INFO 0x0030B104 INFO 0x00400101 0x00400102 INFO INFO 0x00400103 INFO TRUE TRUE Drives on bus %(bus_num) enclosure %(encl_num) are scheduled to shut down for an unspecified reason. FALSE FALSE Base Enclosure's LED is off. Check for hardwarerelated alerts and take appropriate action. If the issue persists, contact your service provider. Data availability and performance may be impacted. https://dell.com/support/kbdoc/00 0130344 - - - TRUE FALSE Base Enclosure's LED is blinking. - - - TRUE FALSE Base Enclosure's LED is on. - - - TRUE FALSE Node's LED is blinking. - - - Check for hardware- TRUE FALSE Node's LED is on. related alerts and take - - appropriate action. FALSE FALSE Node %(which) is shutting down. - - - FALSE FALSE Node %(which) is starting up. - - - FALSE FALSE Node %(which) is rebooting. - - - 0x00400104 INFO FALSE FALSE Node %(which) has booted. - - - 0x00400105 0x00400106 0x00400107 INFO INFO CRITICAL FALSE FALSE An internal component, %(comp), failed on %(which). - - - FALSE FALSE Explicit request to enter Service Mode on Node %(which). TRUE TRUE Node %(which) entered Service Mode. - - - Check for and correct system errors. On the affected node, use service scripts to clear service mode (svc_rescue_state clear) and reboot (svc_node reboot local) to return to normal mode. If the issue persists, contact System high availability and performance is degraded. Node %(which) is not servicing I/O. https://dell.com/support/kbdoc/00 0132218 31 Dell EMC PowerStore Events and Alerts Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Alert and Event Messages
31
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert
raised
Call
home
Message
Repair flow
System impact
Knowledge Base Article
0x0030AF06
MAJOR
TRUE
TRUE
Drives on bus %(bus_num)
enclosure %(encl_num) are
scheduled to shut down because
one or more required hardware
components are not installed.
Check for hardware-
related alerts and take
appropriate action. If the
issue persists, contact
your service provider.
Data availability
and performance
may be degraded.
https://dell.com/support/kbdoc/00
0130344
0x0030AF07
MAJOR
TRUE
TRUE
Drives on bus %(bus_num)
enclosure %(encl_num) are
scheduled to shut down for an
unspecified reason.
Check for hardware-
related alerts and take
appropriate action. If the
issue persists, contact
your service provider.
Data availability
and performance
may be impacted.
https://dell.com/support/kbdoc/00
0130344
0x0030B001
INFO
FALSE
FALSE
Base Enclosure's LED is off.
-
-
-
0x0030B003
INFO
TRUE
FALSE
Base Enclosure's LED is blinking.
-
-
-
0x0030B004
INFO
TRUE
FALSE
Base Enclosure's LED is on.
-
-
-
0x0030B103
INFO
TRUE
FALSE
Node's LED is blinking.
-
-
-
0x0030B104
INFO
TRUE
FALSE
Node's LED is on.
Check for hardware-
related alerts and take
appropriate action.
-
-
0x00400101
INFO
FALSE
FALSE
Node %(which) is shutting down.
-
-
-
0x00400102
INFO
FALSE
FALSE
Node %(which) is starting up.
-
-
-
0x00400103
INFO
FALSE
FALSE
Node %(which) is rebooting.
-
-
-
0x00400104
INFO
FALSE
FALSE
Node %(which) has booted.
-
-
-
0x00400105
INFO
FALSE
FALSE
An internal component, %(comp),
failed on %(which).
-
-
-
0x00400106
INFO
FALSE
FALSE
Explicit request to enter Service
Mode on Node %(which).
-
-
-
0x00400107
CRITICAL
TRUE
TRUE
Node %(which) entered Service
Mode.
Check for and correct
system errors. On the
affected node, use service
scripts to clear service
mode (svc_rescue_state
clear) and reboot
(svc_node reboot local) to
return to normal mode. If
the issue persists, contact
System high
availability and
performance is
degraded. Node
%(which) is not
servicing I/O.
https://dell.com/support/kbdoc/00
0132218