Alert and Event Messages Event code Severity Alert raised 0x01806703 MAJOR TRUE Call home Message FALSE The storage initiator VMkernel adapter %(vmk_name) of the ESXi host %(host_name) has an invalid MTU %(current_mtu). Repair flow Configure VMkernel adapter with the required MTU %(required_mtu). System impact Knowledge Base Article Virtual volume high availability and performance may be impacted. https://dell.com/support/kbdoc/00 0179615 0x01806801 INFO 0x01806802 MINOR 0x01806901 INFO 0x01806902 MAJOR 0x01806A01 INFO 0x01806A02 MAJOR 0x01806B01 INFO 0x01806B02 MAJOR FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE Management ports are properly connected to different management switches. Management ports are connected to the same management switch %(physical_switch_id). Speed configuration between data switch ports and node data ports is consistent. Speed mismatch detected: %(connection_scheme). - - - For high availability, connect the management ports to two management switches. Cable both nodes to the same management switch only if two switches are not Management availability may be impacted in case of high availability event. - available. - - - Ensure that the speed is configured consistently on the data switch ports. Network performance may be degraded. https://dell.com/support/kbdoc/00 0124928 FALSE FALSE Native VLAN configuration between data switch ports and appliance data ports is consistent across the cluster. - - - TRUE FALSE FALSE FALSE Cluster-wide native VLAN mismatch detected between data switch ports: %(connection_scheme). Native VLAN configuration between management switch ports and appliance management ports is consistent across the cluster. Ensure that the native VLAN is configured consistently on the displayed data switch ports. Appliance connectivity may be degraded. https://dell.com/support/kbdoc/00 0124928 - - - TRUE FALSE Cluster-wide native VLAN mismatch detected between management switch ports: %(connection_scheme). Ensure that the native VLAN is configured consistently on the displayed management switch ports. Management connectivity may be degraded. https://dell.com/support/kbdoc/00 0124928 99 Dell EMC PowerStore Events and Alerts Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Alert and Event Messages
99
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert
raised
Call
home
Message
Repair flow
System impact
Knowledge Base Article
0x01806703
MAJOR
TRUE
FALSE
The storage initiator VMkernel
adapter %(vmk_name) of the
ESXi host %(host_name) has an
invalid MTU %(current_mtu).
Configure VMkernel
adapter with the required
MTU %(required_mtu).
Virtual volume high
availability and
performance may
be impacted.
https://dell.com/support/kbdoc/00
0179615
0x01806801
INFO
FALSE
FALSE
Management ports are properly
connected to different
management switches.
-
-
-
0x01806802
MINOR
TRUE
FALSE
Management ports are connected
to the same management switch
%(physical_switch_id).
For high availability,
connect the management
ports to two management
switches. Cable both
nodes to the same
management switch only if
two switches are not
available.
Management
availability may be
impacted in case of
high availability
event.
-
0x01806901
INFO
FALSE
FALSE
Speed configuration between
data switch ports and node data
ports is consistent.
-
-
-
0x01806902
MAJOR
TRUE
FALSE
Speed mismatch detected:
%(connection_scheme).
Ensure that the speed is
configured consistently on
the data switch ports.
Network
performance may
be degraded.
https://dell.com/support/kbdoc/00
0124928
0x01806A01
INFO
FALSE
FALSE
Native VLAN configuration
between data switch ports and
appliance data ports is consistent
across the cluster.
-
-
-
0x01806A02
MAJOR
TRUE
FALSE
Cluster-wide native VLAN
mismatch detected between data
switch ports:
%(connection_scheme).
Ensure that the native
VLAN is configured
consistently on the
displayed data switch
ports.
Appliance
connectivity may
be degraded.
https://dell.com/support/kbdoc/00
0124928
0x01806B01
INFO
FALSE
FALSE
Native VLAN configuration
between management switch
ports and appliance management
ports is consistent across the
cluster.
-
-
-
0x01806B02
MAJOR
TRUE
FALSE
Cluster-wide native VLAN
mismatch detected between
management switch ports:
%(connection_scheme).
Ensure that the native
VLAN is configured
consistently on the
displayed management
switch ports.
Management
connectivity may
be degraded.
https://dell.com/support/kbdoc/00