Alert and Event Messages Event code Severity Alert raised 0x01804103 MAJOR TRUE Call home Message Repair flow FALSE The ESXi host management port group %(pg_name) has an invalid VLAN ID %(vlan_id). The required VLAN ID is %(required_vlan_id). Configure the VLAN ID in vCenter. System impact Knowledge Base Article - https://dell.com/support/kbdoc/00 0179609 0x01804201 INFO 0x01804202 MAJOR 0x01804301 INFO 0x01804302 MINOR FALSE TRUE FALSE FALSE The vMotion port group %(pg_name) is configured on the Distributed Virtual Switch %(dvs_name). FALSE Unable to find the vMotion port group with name %(pg_name) on the Distributed Virtual Switch %(dvs_name). FALSE VLAN configuration on the vMotion port group %(pg_name) is correct. - Configure a vMotion port group on the Distributed Virtual Switch in vCenter based on the system requirements described in the Virtualization with PowerStore Guide. If the issue persists, contact your service provider. - Unable to obtain information about the VLAN configuration of FALSE FALSE the vMotion port group - %(pg_name) on the Distributed Virtual Switch %(dvs_name). - - - https://dell.com/support/kbdoc/00 0179610 - - - 0x01804303 MAJOR 0x01804401 INFO TRUE FALSE The vMotion port group %(pg_name) has an invalid VLAN ID %(vlan_id). The required VLAN ID is %(required_vlan_id). Configure the VLAN ID in vCenter. The storage initiator port group FALSE FALSE %(pg_name) is configured on the Distributed Virtual Switch - %(dvs_name). - https://dell.com/support/kbdoc/00 0179610 - - 86 Dell EMC PowerStore Events and Alerts Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Alert and Event Messages
86
Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert
raised
Call
home
Message
Repair flow
System impact
Knowledge Base Article
0x01804103
MAJOR
TRUE
FALSE
The ESXi host management port
group %(pg_name) has an invalid
VLAN ID %(vlan_id). The required
VLAN ID is %(required_vlan_id).
Configure the VLAN ID in
vCenter.
-
https://dell.com/support/kbdoc/00
0179609
0x01804201
INFO
FALSE
FALSE
The vMotion port group
%(pg_name) is configured on the
Distributed Virtual Switch
%(dvs_name).
-
-
-
0x01804202
MAJOR
TRUE
FALSE
Unable to find the vMotion port
group with name %(pg_name) on
the Distributed Virtual Switch
%(dvs_name).
Configure a vMotion port
group on the Distributed
Virtual Switch in vCenter
based on the system
requirements described in
the Virtualization with
PowerStore Guide. If the
issue persists, contact
your service provider.
-
https://dell.com/support/kbdoc/00
0179610
0x01804301
INFO
FALSE
FALSE
VLAN configuration on the
vMotion port group %(pg_name)
is correct.
-
-
-
0x01804302
MINOR
FALSE
FALSE
Unable to obtain information
about the VLAN configuration of
the vMotion port group
%(pg_name) on the Distributed
Virtual Switch %(dvs_name).
-
-
-
0x01804303
MAJOR
TRUE
FALSE
The vMotion port group
%(pg_name) has an invalid VLAN
ID %(vlan_id). The required VLAN
ID is %(required_vlan_id).
Configure the VLAN ID in
vCenter.
-
https://dell.com/support/kbdoc/00
0179610
0x01804401
INFO
FALSE
FALSE
The storage initiator port group
%(pg_name) is configured on the
Distributed Virtual Switch
%(dvs_name).
-
-
-