Dell PowerVault MD3200i CLI Guide - Page 136
owner, FALSE
View all Dell PowerVault MD3200i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
Parameter capacity owner cacheReadPrefetch segmentSize 136 Script Commands Description Size of the virtual disk that you are adding to the storage array. Size is defined in units of bytes, KB, MB, GB, or TB. NOTE: Add a space between the last digit and the size (bytes, KB, MB, or GB) for values greater than 9. If you do not specify a capacity, all the available physical disk capacity in the disk group is used. If you do not specify the capacity unit, bytes is used as the default unit. RAID controller module that owns the virtual disk. Valid RAID controller module identifiers are 0 or 1, where, 0 is the RAID controller module on the left and 1 is the RAID controller module on the right when viewed from the rear of the enclosure. If you do not specify an owner, the RAID controller module firmware determines the owner. NOTE: The owner parameter defines which RAID controller module owns the virtual disk. The preferred RAID controller module ownership of a virtual disk is the RAID controller module that currently owns the disk group. The setting to turn on or turn off cache read prefetch. To turn on cache read prefetch, set this parameter to TRUE. To turn off cache read prefetch, set this parameter to FALSE. Amount of data (in kilobytes) that the RAID controller module writes on a single physical disk in a virtual disk before writing data on the next physical disk. Valid values are 8, 16, 32, 64, 128, 256, or 512. For information about the segmentSize parameter, see "Using the Auto Configure Command" on page 53.