Dell S4048-ON EMC Networking with Isilon Front-End Deployment and Best Practic - Page 56
There will be one VLAN for each Isilon subnet; this will also include the, Next
View all Dell S4048-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
The upstream interfaces and port channels will be configured as follows: S4048-ON Leaf 3 interface port-channel50 description "Spine 1 and 2" no shutdown switchport mtu 9216 vlt-peer-lag port-channel 50 interface fo 1/49 description "Spine 1" no shutdown port-channel-protocol LACP port-channel 50 mode active mtu 9216 interface fo 1/50 description "Spine 2" no shutdown port-channel-protocol LACP port-channel 50 mode active mtu 9216 S4048-ON Leaf 4 interface port-channel50 description "Spine 1 and 2" no shutdown switchport mtu 9216 vlt-peer-lag port-channel 50 interface fo 1/49 description "Spine 1" no shutdown port-channel-protocol LACP port-channel 50 mode active mtu 9216 interface fo 1/50 description "Spine 2" no shutdown port-channel-protocol LACP port-channel 50 mode active mtu 9216 Next, we will create the VLANs. There will be one VLAN for each Isilon subnet; this will also include the servers in each rack. S4048-ON Leaf 3 interface vlan200 no shutdown untagged port-channel 1,3,5,101,102 tagged port-channel 50 S4048-ON Leaf 4 interface vlan200 no shutdown untagged port-channel 1,3,5,101,102 tagged port-channel 50 Uplink Failure Detection (UFD) is configured next. UFD shuts down all downstream interfaces if all uplinks fail. 56 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0