Dell S5248F-ON EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 11

SNMP and email alerts, Event filters

Page 11 highlights

To override the date and time that is used in the system event log (SEL) log, use the following command: root@dellemc-diag-os:~# ipmitool sel time get 08/01/2018 15:10:46 root@dellemc-diag-os:~# ipmitool sel time set usage: sel time set "mm/dd/yyyy hh:mm:ss" root@dellemc-diag-os:~# For ipmiutil/iseltime, download and install the binaries and documentation from https://ipmiutil.sourceforge.net. Also, various Linux distributions have binary packages prebuilt and available for download. SNMP and email alerts Event filters To set the platform event filters, use the raw command format. To configure an entry in the filter table: root@dellemc-diag-os:~# ipmitool raw 0x04 0x12 0x6 0x2 0xc0 0x1 0x2 0x2 0xff 0xff 0xff 0xff 0xff 0x01 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0 Byte 3 (0x60) - event filter table cmd Byte 4(0x2) - filter number Byte 5(0xc0) - filter config(enable) Byte 6(0x1) - action(alert) Byte 7(0x2) - policy number Byte 8(0x2) - event severity(information) Byte 9(0xff) - slave address Byte 10 (0xff) - channel number(any) Byte 11(0xff) - sensor number(any) Byte 12(0x01) - event trigger(threshold) The entry 2 is changed after the command, as shown: root@dellemc-diag-os:~# root@dellemc-diag-os:~# ipmitool pef filter list 1 | disabled, configurable 2 | enabled, pre-configured | Any | Any | Information | OEM | Any | Alert | 2 3 | disabled, configurable 4 | disabled, configurable 5 | disabled, configurable 6 | disabled, configurable 7 | disabled, configurable 8 | disabled, configurable 9 | disabled, configurable 10 | disabled, configurable 11 | disabled, configurable 12 | disabled, configurable 13 | disabled, configurable 14 | disabled, configurable 15 | disabled, configurable 16 | disabled, configurable 17 | disabled, configurable 18 | disabled, configurable 19 | disabled, configurable 20 | disabled, configurable 21 | disabled, configurable 22 | disabled, configurable 23 | disabled, configurable 24 | disabled, configurable 25 | disabled, configurable 26 | disabled, configurable 27 | disabled, configurable 28 | disabled, configurable 29 | disabled, configurable 30 | disabled, configurable 31 | disabled, configurable 32 | disabled, configurable Configuration methods 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

To override the date and time that is used in the system event log (SEL) log, use the following command:
root@dellemc-diag-os:~# ipmitool sel time get
08/01/2018 15:10:46
root@dellemc-diag-os:~# ipmitool sel time set
usage: sel time set "mm/dd/yyyy hh:mm:ss"
root@dellemc-diag-os:~#
For
ipmiutil/iseltime
, download and install the binaries and documentation from
. Also,
various Linux distributions have binary packages prebuilt and available for download.
SNMP and email alerts
Event filters
To set the platform event filters, use the
raw
command format. To configure an entry in the filter table:
root@dellemc-diag-os:~# ipmitool raw 0x04 0x12 0x6 0x2 0xc0 0x1 0x2 0x2 0xff 0xff 0xff 0xff 0xff 0x01 0x0 0x0
0x0 0x0 0x0 0x0 0x0 0x0 0x0 0x0
Byte 3 (0x60) – event filter table cmd
Byte 4(0x2) – filter number
Byte 5(0xc0) – filter config(enable)
Byte 6(0x1) – action(alert)
Byte 7(0x2) – policy number
Byte 8(0x2)
- event severity(information)
Byte 9(0xff) – slave address
Byte 10 (0xff) – channel number(any)
Byte 11(0xff)
- sensor number(any)
Byte 12(0x01) – event trigger(threshold)
The entry 2 is changed after the command, as shown:
root@dellemc-diag-os:~#
root@dellemc-diag-os:~#
ipmitool pef filter list
1 | disabled, configurable
2 | enabled, pre-configured | Any | Any | Information | OEM | Any | Alert | 2
3 | disabled, configurable
4 | disabled, configurable
5 | disabled, configurable
6 | disabled, configurable
7 | disabled, configurable
8 | disabled, configurable
9 | disabled, configurable
10 | disabled, configurable
11 | disabled, configurable
12 | disabled, configurable
13 | disabled, configurable
14 | disabled, configurable
15 | disabled, configurable
16 | disabled, configurable
17 | disabled, configurable
18 | disabled, configurable
19 | disabled, configurable
20 | disabled, configurable
21 | disabled, configurable
22 | disabled, configurable
23 | disabled, configurable
24 | disabled, configurable
25 | disabled, configurable
26 | disabled, configurable
27 | disabled, configurable
28 | disabled, configurable
29 | disabled, configurable
30 | disabled, configurable
31 | disabled, configurable
32 | disabled, configurable
Configuration methods
11