Dell S5248F-ON EMC PowerSwitch S5200-ON Series BMC User Guide March 2021 - Page 32

Firmware update, Medium, Comments, Update BMC by USB interface, Enable BMC virtual USB

Page 32 highlights

5 Firmware update To update the firmware from a remote machine, use the BMC LAN interface. You can also update the firmware in the local host OS using the USB interface. The USB interface is between the BMC and the microprocessor. When using the USB, the BMC simulates a virtual USB device, then Yafuflash sends the image to the BMC via the USB bus. Typically the update process completes in five minutes. For more information about Yafuflash, see the S5200-ON Series Release Notes. Table 5. Firmware update Tool Medium OS Comments Yafuflash USB Linux Recommended-Host OS only Yafuflash LAN WIndows/Linux Internal use only The BMC virtual USB is disabled by default. Enable the USB before you update the firmware. Update BMC by USB interface Enable BMC virtual USB: ipmitool raw 0x32 0xaa 0x00 (Then wait 15s) Update Main BMC: ./Yafuflash -cd -mse 1 rom.ima Update BMC by LAN interface 1. Ensure that the client Linux or Windows machine can ping the BMC IP address. 2. Open a command window. 3. Update the main BMC using the following command: ./Yafuflash -nw -ip bmc_ip -u admin -p admin -mse 1 bmc.ima 32 Firmware update

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

Firmware update
To update the firmware from a remote machine, use the BMC LAN interface.
You can also update the firmware in the local host OS using the USB interface. The USB interface is between the BMC and the
microprocessor. When using the USB, the BMC simulates a virtual USB device, then Yafuflash sends the image to the BMC via
the USB bus. Typically the update process completes in five minutes.
For more information about Yafuflash, see the
S5200-ON Series Release Notes
.
Table 5. Firmware update
Tool
Medium
OS
Comments
Yafuflash
USB
Linux
Recommended—Host OS
only
Yafuflash
LAN
WIndows/Linux
Internal use only
The BMC virtual USB is disabled by default. Enable the USB before you update the firmware.
Update BMC by USB interface
Enable BMC virtual USB:
ipmitool raw 0x32 0xaa 0x00 (Then wait 15s)
Update Main BMC:
./Yafuflash –cd –mse 1 rom.ima
Update BMC by LAN interface
1.
Ensure that the client Linux or Windows machine can ping the BMC IP address.
2.
Open a command window.
3.
Update the main BMC using the following command:
./Yafuflash -nw -ip bmc_ip -u admin -p admin -mse 1 bmc.ima
5
32