6 Access system health sensors To check sensor information, use the following command: root@dellemc-diag-os:~# ipmitool sensor list To change the sensor threshold, see the IPMI Specification v2.0 chapter 35.8 Set Sensor Thresholds Command. ● Request data byte 1-Sensor number, FFH=reserved ● Request data byte 2- ○ [7:6] - reserved. Write as 00b ○ [5] - 1b=set upper non-recoverable threshold ○ [4] - 1b=set upper critical threshold ○ [3] - 1b=set upper non-critical threshold ○ [2] - 1b=set lower non-recoverable threshold ○ [1] - 1b=set lower critical threshold ○ [0] - 1b=set lower non-critical threshold ● Request data byte 3-lower non-critical threshold. Ignored if bit 0 of byte 2 = 0 ● Request data byte 4-lower critical threshold. Ignored if bit 1 of byte 2 = 0 ● Request data byte 5-lower non-recoverable threshold. Ignored if bit 2 of byte 2 = 0 ● Request data byte 6-upper non-critical threshold. Ignored if bit 3 of byte 2 = 0 ● Request data byte 7-upper critical threshold value. Ignored if bit 4 of byte 2 = 0 ● Request data byte 8-upper non-recoverable threshold value. Ignored if bit 5 of byte 2 = 0 ● Response data byte 1-Completion code ipmitool sensors root@dellemc-diag-os:~# ipmitool sensor list PT_Mid_temp | 32.000 | degrees C | ok | na NPU_Near_temp | 29.000 | degrees C | ok | na PT_Left_temp | 28.000 | degrees C | ok | na PT_Right_temp | 30.000 | degrees C | ok | na ILET_AF_temp | 26.000 | degrees C | ok | na PSU1_AF_temp | 24.000 | degrees C | ok | na PSU2_AF_temp | 25.000 | degrees C | ok | na PSU1_temp | 33.000 | degrees C | ok | na PSU2_temp | na | degrees C | na | na CPU_temp | 31.000 | degrees C | ok | na FAN1_Rear_rpm | 9120.000 | RPM | ok | na FAN2_Rear_rpm | 9000.000 | RPM | ok | na FAN3_Rear_rpm | 9000.000 | RPM | ok | na FAN4_Rear_rpm | 9000.000 | RPM | ok | na FAN1_Front_rpm | 10080.000 | RPM | ok | na FAN2_Front_rpm | 10080.000 | RPM | ok | na FAN3_Front_rpm | 10080.000 | RPM | ok | na FAN4_Front_rpm | 10080.000 | RPM | ok | na PSU1_rpm | 9000.000 | RPM | ok | na PSU2_rpm | na | RPM | na | na PSU_Total_watt | 110.000 | Watts | ok | na PSU1_stat | 0x0 | discrete | 0x0180| na PSU2_stat | 0x0 | discrete | 0x0380| na PSU1_In_watt | 110.000 | Watts | ok | na PSU1_In_volt | 205.700 | Volts | ok | na PSU1_In_amp | 0.480 | Amps | ok | na PSU1_Out_watt | 90.000 | Watts | ok | na PSU1_Out_volt | 12.400 | Volts | ok | na PSU1_Out_amp | 7.500 | Amps | ok | na PSU2_In_watt | na | Watts | na | na PSU2_In_volt | na | Volts | na | na PSU2_In_amp | na | Amps | na | na PSU2_Out_watt | na | Watts | na | na PSU2_Out_volt | na | Volts | na | na PSU2_Out_amp | na | Amps | na | na ACPI_stat | 0x0 | discrete | 0x0180| na FAN1_prsnt | 0x0 | discrete | 0x0180| na FAN2_prsnt | 0x0 | discrete | 0x0180| na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | 78.000 | 80.000 | 85.000 | na | na | na | na | na | na | na | na | na | na | na | na | 61.000 | 64.000 | na | na | na | na | na | na | na | na | na | na | 90.000 | 94.000 | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na Access system health sensors 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

Access system health sensors
To check sensor information, use the following command:
root@dellemc-diag-os:~# ipmitool sensor list
To change the sensor threshold, see the
IPMI Specification v2.0
chapter 35.8
Set Sensor Thresholds Command
.
Request data byte 1—Sensor number, FFH=reserved
Request data byte 2—
[7:6] - reserved. Write as 00b
[5] - 1b=set upper non-recoverable threshold
[4] - 1b=set upper critical threshold
[3] - 1b=set upper non-critical threshold
[2] - 1b=set lower non-recoverable threshold
[1] - 1b=set lower critical threshold
[0] - 1b=set lower non-critical threshold
Request data byte 3—lower non-critical threshold. Ignored if bit 0 of byte 2 = 0
Request data byte 4—lower critical threshold. Ignored if bit 1 of byte 2 = 0
Request data byte 5—lower non-recoverable threshold. Ignored if bit 2 of byte 2 = 0
Request data byte 6—upper non-critical threshold. Ignored if bit 3 of byte 2 = 0
Request data byte 7—upper critical threshold value. Ignored if bit 4 of byte 2 = 0
Request data byte 8—upper non-recoverable threshold value. Ignored if bit 5 of byte 2 = 0
Response data byte 1—Completion code
ipmitool sensors
root@dellemc-diag-os:~#
ipmitool sensor list
PT_Mid_temp
| 32.000
| degrees C | ok
| na
| na
| na
| 78.000 | 80.000 | 85.000
NPU_Near_temp
| 29.000
| degrees C | ok
| na
| na
| na
| na
| na
| na
PT_Left_temp
| 28.000
| degrees C | ok
| na
| na
| na
| na
| na
| na
PT_Right_temp
| 30.000
| degrees C | ok
| na
| na
| na
| na
| na
| na
ILET_AF_temp
| 26.000
| degrees C | ok
| na
| na
| na
| na
| na
| na
PSU1_AF_temp
| 24.000
| degrees C | ok
| na
| na
| na
| 61.000 | 64.000 | na
PSU2_AF_temp
| 25.000
| degrees C | ok
| na
| na
| na
| na
| na
| na
PSU1_temp
| 33.000
| degrees C | ok
| na
| na
| na
| na
| na
| na
PSU2_temp
| na
| degrees C | na
| na
| na
| na
| na
| na
| na
CPU_temp
| 31.000
| degrees C | ok
| na
| na
| na
| 90.000 | 94.000 | na
FAN1_Rear_rpm
| 9120.000
| RPM
| ok
| na
| 1080.000 | na
| na
| na
| na
FAN2_Rear_rpm
| 9000.000
| RPM
| ok
| na
| 1080.000 | na
| na
| na
| na
FAN3_Rear_rpm
| 9000.000
| RPM
| ok
| na
| 1080.000 | na
| na
| na
| na
FAN4_Rear_rpm
| 9000.000
| RPM
| ok
| na
| 1080.000 | na
| na
| na
| na
FAN1_Front_rpm
| 10080.000 | RPM
| ok
| na
| 1080.000 | na
| na
| na
| na
FAN2_Front_rpm
| 10080.000 | RPM
| ok
| na
| 1080.000 | na
| na
| na
| na
FAN3_Front_rpm
| 10080.000 | RPM
| ok
| na
| 1080.000 | na
| na
| na
| na
FAN4_Front_rpm
| 10080.000 | RPM
| ok
| na
| 1080.000 | na
| na
| na
| na
PSU1_rpm
| 9000.000
| RPM
| ok
| na
| na
| na
| na
| na
| na
PSU2_rpm
| na
| RPM
| na
| na
| na
| na
| na
| na
| na
PSU_Total_watt
| 110.000
| Watts
| ok
| na
| na
| na
| na
| na
| na
PSU1_stat
| 0x0
| discrete
| 0x0180| na
| na
| na
| na
| na
| na
PSU2_stat
| 0x0
| discrete
| 0x0380| na
| na
| na
| na
| na
| na
PSU1_In_watt
| 110.000
| Watts
| ok
| na
| na
| na
| na
| na
| na
PSU1_In_volt
| 205.700
| Volts
| ok
| na
| na
| na
| na
| na
| na
PSU1_In_amp
| 0.480
| Amps
| ok
| na
| na
| na
| na
| na
| na
PSU1_Out_watt
| 90.000
| Watts
| ok
| na
| na
| na
| na
| na
| na
PSU1_Out_volt
| 12.400
| Volts
| ok
| na
| na
| na
| na
| na
| na
PSU1_Out_amp
| 7.500
| Amps
| ok
| na
| na
| na
| na
| na
| na
PSU2_In_watt
| na
| Watts
| na
| na
| na
| na
| na
| na
| na
PSU2_In_volt
| na
| Volts
| na
| na
| na
| na
| na
| na
| na
PSU2_In_amp
| na
| Amps
| na
| na
| na
| na
| na
| na
| na
PSU2_Out_watt
| na
| Watts
| na
| na
| na
| na
| na
| na
| na
PSU2_Out_volt
| na
| Volts
| na
| na
| na
| na
| na
| na
| na
PSU2_Out_amp
| na
| Amps
| na
| na
| na
| na
| na
| na
| na
ACPI_stat
| 0x0
| discrete
| 0x0180| na
| na
| na
| na
| na
| na
FAN1_prsnt
| 0x0
| discrete
| 0x0180| na
| na
| na
| na
| na
| na
FAN2_prsnt
| 0x0
| discrete
| 0x0180| na
| na
| na
| na
| na
| na