Dell S5248F-ON EMC Networking OS10EE FCoE Deployment with FSB - Page 37
:F4:E9:D4:62:4B:BA, 01:F4:E9:D4:62:4B:BB, 01:F4:E9:D4:62:4B:72, 01:F4:E9:D4:62:4B:73
![]() |
View all Dell S5248F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
The FC WWPNs used in this deployment example are shown in Table 1. The Switch column has been added for reference per the cable connections in the SAN topology diagram (Figure 7). Server FCoE CNA port WWPNs Server Port Switch WWPN R740xd-1 1 S4148U-Leaf1 20:01:F4:E9:D4:61:C6:6A R740xd-1 2 S4148U-Leaf2 20:01:F4:E9:D4:61:C6:6B R740xd-2 1 S4148U-Leaf1 20:01:F4:E9:D4:62:4A:D0 R740xd-2 2 S4148U-Leaf2 20:01:F4:E9:D4:62:4A:D1 R740xd-3 1 S4148U-Leaf1 20:01:F4:E9:D4:62:4B:BA R740xd-3 2 S4148U-Leaf2 20:01:F4:E9:D4:62:4B:BB R740xd-4 1 S4148U-Leaf1 20:01:F4:E9:D4:62:4B:72 R740xd-4 2 S4148U-Leaf2 20:01:F4:E9:D4:62:4B:73 B.2 Dell EMC Unity 500F storage array configuration The WWPNs of FC adapters in storage arrays are also used for FC zone configuration. WWPNs on Unity storage arrays are determined as follows: 1. Connect to the Unisphere GUI in a web browser and log in. Click the Settings icon right corner of the page. 2. In the left pane of the Settings window, select Access > Fibre Channel. near the top The Fibre Channel Ports page is displayed as shown in Figure 11. A zoomed-in view of the area inside the red box is shown in Figure 12. Unisphere Fibre Channel Ports page Zoomed-in view of SP A and SP B WWNs on Fibre Channel Ports page 37 Dell EMC Networking OS10EE FCoE Deployment with FSB
![](/manual_guide/products/dell-powerswitch-s4148uon-emc-networking-os10ee-fcoe-deployment-fsb-592468b/37.png)