Dell Z9264F-ON EMC PowerSwitch BMC User Guide March 2021 - Page 12

Alert policies and destinations, LAN destinations, IPMI Specification v2.0, Event Filter Table

Page 12 highlights

33 | disabled, configurable 34 | disabled, configurable 35 | disabled, configurable 36 | disabled, configurable 37 | disabled, configurable 38 | disabled, configurable 39 | disabled, configurable 40 | disabled, configurable For more information, see the IPMI Specification v2.0 chapter 17.7 Event Filter Table and chapter 30.3 Set PEF Configuration Parameters Command. Alert policies and destinations For more information, see the IPMI Specification v2.0 chapter 17.11 Alert Policy Table and chapter 30.3 Set PEF Configuration Parameters Command (parameter 9). LAN destinations BMC supports SNMP alert destinations. These alert destinations are SNMP traps. When you set a LAN destination for alerts, the BMC sends an SNMP trap to the set a destination whenever BMC detects alert conditions. You can setup the SNMP management application on the destination to receive these SNMP traps; however, setting up the SNMP management station is beyond the scope of this document. To view alert destinations, use the ipmitool lan alert print command. root@dellemc-diag-os:~# ipmitool lan alert print Alert Destination : 0 Alert Acknowledge : Unacknowledged Destination Type : PET Trap Retry Interval : 0 Number of Retries : 0 Alert Gateway : Default Alert IP Address : 0.0.0.0 Alert MAC Address : 00:00:00:00:00:00 Alert Destination : 1 Alert Acknowledge : Unacknowledged Destination Type : PET Trap Retry Interval : 0 Number of Retries : 0 Alert Gateway : Default Alert IP Address : 0.0.0.0 Alert MAC Address : 00:00:00:00:00:00 Alert Destination : 2 Alert Acknowledge : Unacknowledged Destination Type : PET Trap Retry Interval : 0 Number of Retries : 0 Alert Gateway : Default Alert IP Address : 0.0.0.0 Alert MAC Address : 00:00:00:00:00:00 . . . Alert Destination : 15 Alert Acknowledge : Unacknowledged Destination Type : PET Trap Retry Interval : 0 Number of Retries : 0 Alert Gateway : Default Alert IP Address : 0.0.0.0 Alert MAC Address : 00:00:00:00:00:00 You can configure up to 15 destinations. To configure destination 1 to send an alert to a machine with IP address 10.11.227.180: root@dellemc-diag-os:~# ipmitool lan alert set 1 1 ipaddr 10.11.227.105 Setting LAN Alert 1 IP Address to 10.11.227.105 12 Configuration methods

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

33 | disabled, configurable
34 | disabled, configurable
35 | disabled, configurable
36 | disabled, configurable
37 | disabled, configurable
38 | disabled, configurable
39 | disabled, configurable
40 | disabled, configurable
For more information, see the
IPMI Specification v2.0
chapter 17.7
Event Filter Table
and chapter 30.3
Set PEF Configuration
Parameters Command
.
Alert policies and destinations
For more information, see the
IPMI Specification v2.0
chapter 17.11
Alert Policy Table
and chapter 30.3
Set PEF Configuration
Parameters Command (parameter 9)
.
LAN destinations
BMC supports SNMP alert destinations. These alert destinations are SNMP traps. When you set a LAN destination for alerts,
the BMC sends an SNMP trap to the set a destination whenever BMC detects alert conditions. You can setup the SNMP
management application on the destination to receive these SNMP traps; however, setting up the SNMP management station is
beyond the scope of this document.
To view alert destinations, use the
ipmitool lan alert print
command.
root@dellemc-diag-os:~#
ipmitool lan alert print
Alert Destination
: 0
Alert Acknowledge
: Unacknowledged
Destination Type
: PET Trap
Retry Interval
: 0
Number of Retries
: 0
Alert Gateway
: Default
Alert IP Address
: 0.0.0.0
Alert MAC Address
: 00:00:00:00:00:00
Alert Destination
: 1
Alert Acknowledge
: Unacknowledged
Destination Type
: PET Trap
Retry Interval
: 0
Number of Retries
: 0
Alert Gateway
: Default
Alert IP Address
: 0.0.0.0
Alert MAC Address
: 00:00:00:00:00:00
Alert Destination
: 2
Alert Acknowledge
: Unacknowledged
Destination Type
: PET Trap
Retry Interval
: 0
Number of Retries
: 0
Alert Gateway
: Default
Alert IP Address
: 0.0.0.0
Alert MAC Address
: 00:00:00:00:00:00
.
.
.
Alert Destination
: 15
Alert Acknowledge
: Unacknowledged
Destination Type
: PET Trap
Retry Interval
: 0
Number of Retries
: 0
Alert Gateway
: Default
Alert IP Address
: 0.0.0.0
Alert MAC Address
: 00:00:00:00:00:00
You can configure up to 15 destinations. To configure destination 1 to send an alert to a machine with IP address 10.11.227.180:
root@dellemc-diag-os:~#
ipmitool lan alert set 1 1 ipaddr 10.11.227.105
Setting LAN Alert 1 IP Address to 10.11.227.105
12
Configuration methods