Dell Z9264F-ON EMC PowerSwitch BMC User Guide March 2021 - Page 13
Add and delete users, Alert policy setup
![]() |
View all Dell Z9264F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
The following output using the ipmitool lan alert print command shows that the configuration was successful: root@dellemc-diag-os:~# ipmitool lan alert print 1 1 Alert Destination : 1 Alert Acknowledge : Unacknowledged Destination Type : PET Trap Retry Interval : 0 Number of Retries : 0 Alert Gateway : Default Alert IP Address : 10.11.227.105 Alert MAC Address : 00:00:00:00:00:00 Alert policy setup To setup the alert policy, you must use the ipmitool raw command. To view the current policy table, use the ipmitool pef policy list command. root@dellemc-diag-os:~# ipmitool pef policy list 1 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 2 | 2 | enabled | Match-always | 1 | 802.3 LAN | PET | AMI | 0 | 0 | 10.11.227.105 | 00:00:00:00:00:00 3 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 4 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 5 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 6 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 7 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 8 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 9 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 10 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 . . . 57 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 58 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 59 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 60 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 There are 60 entries available for a policy table. The following example shows setting a policy entry. For a detailed description of the table entries, see the IPMI Specification v2.0 Alert policy table entry. root@dellemc-diag-os:~# ipmitool raw 0x4 0x12 0x9 0x2 0x28 0x11 0x00 root@dellemc-diag-os:~# ipmitool pef policy list 1 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 2 | 2 | enabled | Match-always | 1 | 802.3 LAN | PET | AMI | 0 | 0 | 10.11.227.105 | 00:00:00:00:00:00 3 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 4 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 5 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 6 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 7 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 8 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 9 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 10 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 . . . 57 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 58 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 59 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 60 | 0 | disabled | Match-always | 0 | IPMB (I2C) | 0 Add and delete users The following describes adding and deleting users: Configuration methods 13
![](/manual_guide/products/dell-z9264fon-emc-powerswitch-bmc-user-guide-2021-1000531/13.png)