Dell Z9264F-ON EMC PowerSwitch BMC User Guide March 2021 - Page 41

Firmware update, Dell EMC PowerSwitch Firmware Updater Release Notes

Page 41 highlights

A Firmware update BMC, BIOS, and CPLD firmware update is required before you install the Z9264F-ON switch. CAUTION: The preferred method of updating the BMC code is through the ONIE Firmware Updater. For firmware update instructions, see the Dell EMC PowerSwitch Firmware Updater Release Notes. Only use the following update method if there is an issue with the Firmware Updater. To update the firmware from a remote machine, use the BMC LAN interface. You can also update the firmware in the local host operating system using the USB interface. The USB interface is between the BMC and the microprocessor. When using the USB, the BMC simulates a virtual USB device, then Yafuflash sends the image to the BMC using the USB bus. Typically the update process completes in five minutes. For more information about Yafuflash, see the Dell EMC PowerSwitch Z9264F-ON Release Notes. Table 5. Firmware update Tool Medium Operating system Comments Yafuflash USB Linux Recommended-Host operating system only Yafuflash LAN Windows or Linux Internal use only The BMC virtual USB is disabled by default. Enable the USB before you update the firmware. Update BMC by USB interface Enable BMC virtual USB: ipmitool raw 0x32 0xaa 0x00 (Then wait 15s) Update Main BMC: ./Yafuflash -cd -mse 1 rom.ima Update BMC by LAN interface 1. Ensure that the client Linux or Windows machine can ping the BMC IP address. 2. Open a command window. 3. Update the main BMC using the following command. Enter the service tag number in uppercase. ./Yafuflash -nw -ip bmc_ip -u admin -p admin -mse 1 bmc.ima Topics: • USB-based firmware update • BIOS access process • Update BMC in DIAG OS • Network interface settings • Configure BMC network manually Firmware update 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

Firmware update
BMC, BIOS, and CPLD firmware update is required before you install the Z9264F-ON switch.
CAUTION:
The preferred method of updating the BMC code is through the ONIE Firmware Updater. For
firmware update instructions, see the
Dell EMC PowerSwitch Firmware Updater Release Notes
. Only use the
following update method if there is an issue with the Firmware Updater.
To update the firmware from a remote machine, use the BMC LAN interface.
You can also update the firmware in the local host operating system using the USB interface. The USB interface is between the
BMC and the microprocessor. When using the USB, the BMC simulates a virtual USB device, then Yafuflash sends the image to
the BMC using the USB bus. Typically the update process completes in five minutes.
For more information about Yafuflash, see the
Dell EMC PowerSwitch Z9264F-ON Release Notes
.
Table 5. Firmware update
Tool
Medium
Operating system
Comments
Yafuflash
USB
Linux
Recommended—Host
operating system only
Yafuflash
LAN
Windows or Linux
Internal use only
The BMC virtual USB is disabled by default. Enable the USB before you update the firmware.
Update BMC by USB interface
Enable BMC virtual USB:
ipmitool raw 0x32 0xaa 0x00 (Then wait 15s)
Update Main BMC:
./Yafuflash –cd –mse 1 rom.ima
Update BMC by LAN interface
1.
Ensure that the client Linux or Windows machine can ping the BMC IP address.
2.
Open a command window.
3.
Update the main BMC using the following command. Enter the service tag number in uppercase.
./Yafuflash -nw -ip bmc_ip -u admin -p admin -mse 1 bmc.ima