Dewalt DCN45RND1 Instruction Manual - Page 19

Nail Specifications, Return Spring Replacement, Replacing the Profile

Page 19 highlights

SYMPTOM Jammed nail CAUSE Wrong size or angle nails. Material and fastener length. Debris in nosepiece. Worn magazine. Damaged or worn return springs. Damaged or worn profile. English FIX Use only the recommended nails. Refer to Nail Specifications. If the unit continues to stall (forcing the need to rotate the stall release lever) choose the appropriate material and fastener length that is not too rigorous an application. Clean nose area and watch closely for small pieces of broken nails stuck in the track. Replace magazine. See authorized service center. Replace springs. Refer to Return Spring Replacement or see authorized service center. Replace profile. Refer to Replacing the Profile or see authorized service center. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

ENGLISH
17
SYMPTOM
CAUSE
FIX
Jammed nail
Wrong size or angle nails.
Use only the recommended nails. Refer to
Nail Specifications
.
Material and fastener length.
If the unit continues to stall (forcing the need to rotate the stall
release lever) choose the appropriate material and fastener
length that is not too rigorous an application.
Debris in nosepiece.
Clean nose area and watch closely for small pieces of broken
nails stuck in the track.
Worn magazine.
Replace magazine. See authorized service center.
Damaged or worn return springs.
Replace springs. Refer to
Return Spring Replacement
or
see
authorized service center.
Damaged or worn profile.
Replace profile. Refer to
Replacing the Profile
or
see
authorized service center.