Electrolux E48DF76EPS Installation Instructions - Page 34

STEP 10 Perform Leak Tests, STEP 11 Perform Flame Tests - problems

Page 34 highlights

STEP 10 Perform Leak Tests 10-1 Make sure that all knobs on the front of the range are in the off position. 10-2 With electrical power to the range disconnected, open the LPG supply valve. 10-3 Using a gas leak detector or bubble forming leak detection fluid, check the following for leaks: • LPG gas supply connection • All manifold connections • All valve connections • Bypass orifices 10-4 Re-assemble the burner heads, burner head nuts, burner rings, and burner caps without the spill tray in place. Be sure the igniter wire is connected to each burner head. 10-5 Connect the range to the electrical outlet. 10-6 Turn each burner on HIGH, one at a time. Check for leaks around the valves (including the bypass orifice) and the burner lines. Igniter Connect igniter wire here Burner Head Figure 10-1 Igniter Connection STEP 11 Perform Flame Tests 11-1 Turn each burner on HIGH and then off again, several times. If the flame does not light repeatedly and rapidly, check for obstructions between the igniter and the burner head (see Figure 10-1). 11-2 Make sure that the flame: • Is stable. • Does not waver or lift up from the burner. • Is predominately blue in color. • Is not predominately yellow at the tips. If the flame does not have the correct appearance, check the shutter gap settings (see STEP 9). If adjusting the air shutters will not correct the problem, contact the factory. Figure 11-1 Examples of a Normal Flame Page 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Page 10
STEP 10 Perform Leak Tests
10-1
Make sure that all knobs on the front of the
range are in the off position.
10-2
With electrical power to the range disconnected
,
open the LPG supply valve.
10-3
Using a gas leak detector or bubble forming leak
detection fluid, check the following for leaks:
LPG gas supply connection
All manifold connections
All valve connections
Bypass orifices
10-4
Re-assemble the burner heads, burner head
nuts, burner rings, and burner caps without
the
spill tray in place. Be sure the igniter wire is
connected to each burner head.
10-5
Connect the range to the electrical outlet.
10-6
Turn each burner on
HIGH
, one at a time.
Check for leaks around the valves (including the
bypass orifice) and the burner lines.
Figure 10-1
Igniter Connection
STEP 11 Perform Flame Tests
11-1
Turn each burner on
HIGH
and then off again,
several times. If the flame does not light
repeatedly and rapidly, check for obstructions
between the igniter and the burner head (see
Figure 10-1).
11-2
Make sure that the flame:
Is stable.
Does not waver or lift up from the burner.
Is predominately blue in color.
Is not predominately yellow at the tips.
If the flame does not have the correct appearance, check the shutter gap settings (see STEP 9). If adjusting the
air shutters will not correct the problem, contact the factory.
Figure 11-1
Examples of a Normal Flame
Igniter
Connect igniter wire here
Burner Head