Model 1503, EN61557 Specification, of Rdg + Digits
View all Fluke 1503 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
1507/1503 Users Manual Model 1503 Output Voltage Display Range Resolution Test Current Accuracy ± (% of Rdg + Digits) 500 V (0 % to + 20 %) 0.1 to 20.00 MΩ 20.0 to 200.0 MΩ 200 to 500 MΩ 0.01 MΩ 0.1 MΩ 1 MΩ 1 mA @ 500 kΩ ± (2.0 % + 5) 1000 V 0 % to + 20 %) 0.1 to 200.0 MΩ 200 to 2000 MΩ 0.1 MΩ 1 MΩ 1 mA @ 1 MΩ ± (2.0 % + 5) EN61557 Specification The following tables are a requirement for European labeling. Measurement Intrinsic Uncertainty Operating Uncertainty1 Volts ± (2.0 % + 3) 30 % Earth-Bond Resistance ± (1.5 % + 3) 30 % Insulation Resistance Depends on test voltage and range. See Insulation Test specifications. 30 % 1. This specification comes from the standard and indicates the maximum amount allowable by the standard. 24
1507/1503
Users Manual
24
Model 1503
Output Voltage
Display Range
Resolution
Test Current
Accuracy
±
(% of Rdg + Digits)
0.1 to 20.00 M
Ω
0.01 M
Ω
20.0 to 200.0 M
Ω
0.1 M
Ω
500 V
(0 % to + 20 %)
200 to 500 M
Ω
1 M
Ω
1 mA @ 500 k
Ω
±
(2.0 % + 5)
0.1 to 200.0 M
Ω
0.1 M
Ω
1000 V
0 % to + 20 %)
200 to 2000 M
Ω
1 M
Ω
1 mA @ 1 M
Ω
±
(2.0 % + 5)
EN61557 Specification
The following tables are a requirement for European labeling.
Measurement
Intrinsic Uncertainty
Operating Uncertainty
1
Volts
±
(2.0 % + 3)
30 %
Earth-Bond Resistance
±
(1.5 % + 3)
30 %
Insulation Resistance
Depends on test voltage and range.
See Insulation Test specifications.
30 %
1. This specification comes from the standard and indicates the maximum amount allowable by the standard.