Fluke 83V FE 83V & 87V Users Manual - Page 51
Specifications, Maximum Voltage between any Terminal and Earth Ground
View all Fluke 83V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
Specifications Specifications Maximum Voltage between any Terminal and Earth Ground: 1000 V rms W Fuse Protection for mA or µA inputs: 44/100 A, 1000 V FAST Fuse W Fuse Protection for A input: 11 A, 1000 V FAST Fuse Display: Digital: 6000 counts updates 4/sec; (Model 87 also has 19,999 counts in high-resolution mode). Analog Bargraph: 33 segments, updates 40/sec. Frequency: 19,999 counts, updates 3/sec at > 10 Hz Temperature: Operating: -20 °C to +55 °C; Storage: -40 °C to +60 °C Altitude: Operating: 2000 m; Storage: 10,000 m Temperature Coefficient: 0.05 x (specified accuracy)/ °C (< 18 °C or > 28 °C) Electromagnetic Compatibility: In an RF field of 3 V/m total accuracy = specified accuracy + 20 counts Except: 600 µA dc range total accuracy=specified accuracy + 60 counts. Temperature not specified. Relative Humidity: 0 % to 90 % (0 °C to 35 °C); 0 % to 70 % (35 °C to 55 °C) Battery Type: 9 V zinc, NEDA 1604 or 6F22 or 006P Battery Life: 400 hrs typical with alkaline (with backlight off) Vibration: Per MIL-PRF-28800 for a Class 2 instrument Shock: 1 Meter drop per IEC 61010-1:2001 Size (HxWxL): 1.25 in x 3.41 in x 7.35 in (3.1 cm x 8.6 cm x 18.6 cm) Size with Holster and Flex-Stand: 2.06 in x 3.86 in x 7.93 in (5.2 cm x 9.8 cm x 20.1 cm) Weight: 12.5 oz (355 g) Weight with Holster and Flex-Stand: 22.0 oz (624 g) Safety: Complies with ANSI/ISA S82.01-2004, CSA 22.2 No. 1010.1:2004 to 1000 V Overvoltage Category III, IEC 664 to 600 V Overvoltage Category IV. UL listed to UL61010-1. Licensed by TÜV to EN61010-1. 43