    XG2600 Hardware Guide Introduction TA41001-7426 Hardware Guide
  • Fujitsu XG2600 | Hardware Guide - Page 2
    XG2600 Hardware Guide Preface You have purchased the XG2600, a compact, 26 port 10 Gigabit Ethernet layer 2 switch that achieves unsurpassed standards of high throughput and low-latency performance. This manual explains the procedures required to install your XG2600 and should be read and understood
  • Fujitsu XG2600 | Hardware Guide - Page 3
    XG2600 Hardware Guide LICENSE AGREEMENT Product Name XG Series Basic Software Total number of licenses 1 Thank you for purchasing the XG Series switch product ("Hardware") and accompanying software ("Software," together with Hardware, collectively, referred to as "Product") manufactured by
  • Fujitsu XG2600 | Hardware Guide - Page 4
    XG2600 Hardware Guide c. if in Fujitsu's sole judgment it is not commercially reasonable to perform either of the above options, subject to the limitation of liability set forth in subsection (2) above, Fujitsu , mass transport control, medical life support system, and missile launch control in
  • Fujitsu XG2600 | Hardware Guide - Page 5
    and Functions 18 1.1.1 Parts List ...18 1.1.2 Installation of Switch: Front Access or Rear Access (User Configured Airflow 19 1.1.3 Switch Fan Unit Side ...20 1.1.4 Switch Port Side ...22 1.1.5 Top Surface ...25 1.1.6 BOTTOM Surface ...26 1.2 Option ...27 1.2.1 SFP+ Modules ...27 Chapter
  • Fujitsu XG2600 | Hardware Guide - Page 6
    XG2600 Hardware Guide Contents 2.3.4 Plugging in the USB Memory ...50 2.4 Connecting a Setup PC ...51 2.5 Time Setting ...55 2.6 Set up IP address ...56 Index...57 6
  • Fujitsu XG2600 | Hardware Guide - Page 7
    XG2600 Hardware Guide Organization and Usage of This Manual This manual explains what you need to know before using this device. In addition, the README file on CD-ROM contains important information. You will also need to read the file. About This Manual This manual contains important information
  • Fujitsu XG2600 | Hardware Guide - Page 8
    XG2600 Hardware Guide Trademark Notification in This Manual Microsoft, MS-DOS, Windows, Windows NT, Windows Server USA and other countries. Other company names and product names in this manual are trademarks or registered trademarks of their respective companies. Abbreviated Product Names The product
  • Fujitsu XG2600 | Hardware Guide - Page 9
    XG2600 Hardware Guide How the Manuals for This Device Are Organized The manuals for this device are organized as follows. Use these manuals as necessary. Manual Name Description XG2600 Hardware Guide (This manual) This manual describes the hardware of the XG2600. User's Guide This manual
  • Fujitsu XG2600 | Hardware Guide - Page 10
    XG2600 Hardware Guide Safety Precautions About Warning Descriptions This manual contains precautions that must be taken in order to use or next to the symbol. The symbol in form indicates actions or instructions that must be followed. Specific information is shown inside or next to the symbol. 10
  • Fujitsu XG2600 | Hardware Guide - Page 11
    XG2600 Hardware Guide Always follow the instructions for safe use of this device. Indicates that improper an engineer certified by Fujitsu. Continuing to use the device in this condition may result in electric shock or fire. Disconnect 2 power supply cords before service to avoid electric shock.(
  • Fujitsu XG2600 | Hardware Guide - Page 12
    XG2600 Hardware Guide of, the device For multiple devices ensure adequate service areas, front and back, for both devices use any extension card other than the ones supported by this device. Failure to follow this a radio or a TV set. The device may generate noise in a radio or TV set. Avoid looking
  • Fujitsu XG2600 | Hardware Guide - Page 13
    XG2600 Hardware Guide Notes on Maintenance • Customers should not repair this device. In the event of failure, consult with a Fujitsu service engineer or an engineer certified by Fujitsu for maintenance. • Do not dismantle or modify this device for any reason. This device contains high voltage and
  • Fujitsu XG2600 | Hardware Guide - Page 14
    XG2600 Hardware Guide Electromagnetic Compatibility (USA) FCC Part-15 Class A Warning FCC WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply
  • Fujitsu XG2600 | Hardware Guide - Page 15
    XG2600 Hardware Guide Laser Safety The XG2600 may be installed with optical transceiver modules (SFP+ modules), which emit invisible laser light. In the USA, these optical modules are certified as Class 1 laser products that conform to the requirements of the Department of Health and Human Services
  • Fujitsu XG2600 | Hardware Guide - Page 16
    of the protection circuit. In this case, contact Fujitsu or Fujitsu's certified support engineer for further instruction. • Do not turn the power off or reset the system during a firmware update, or the device cannot be enabled. • A User's Guide for this product is provided on the accompanied CD
  • Fujitsu XG2600 | Hardware Guide - Page 17
    in the Package, Descriptions and Functions 18 1.1.1 Parts List 18 1.1.2 Installation of Switch: Front Access or Rear Access (User Configured Airflow 19 1.1.3 Switch Fan Unit Side 20 1.1.4 Switch Port Side 22 1.1.5 Top Surface 25 1.1.6 BOTTOM Surface 26 1.2 Option 27 1.2.1 SFP+ Modules 27
  • Fujitsu XG2600 | Hardware Guide - Page 18
    -ROM ‰ M6 Countersunk Screws (Qty 4) ‰ M6 Machine Screws (Qty 6) ‰ XG2600 Hardware Guide (with Licence Agreement) • XG2600 The XG2600 switch. • Power Cables (Qty 2) Cables to connect the XG2600 to an AC power source. • SFP+ Dummy Caps (Qty 26) Dummy caps to prevent dust when the SFP+ slots are
  • Fujitsu XG2600 | Hardware Guide - Page 19
    Started • CD-ROM It contains the Firmware and User Guide (in a PDF format) necessary for operating and configuring the switch. Adobe Reader is required for viewing. • XG2600 Hardware Guide (with Licence Agreement) This manual describes the hardware of the XG2600. • RS232C Cable is not included
  • Fujitsu XG2600 | Hardware Guide - Page 20
    XG2600 Hardware Guide 1.1.3 Switch Fan Unit Side MAC Firmware Label Fan Unit Chapter 1 Getting Started PSU Slots for model name, Front-Access Configuration serial number label XG2600 FAN2 FAN1 PSU2 PSU1 • MAC Firmware Label This indicates the MAC addresses and firmware revision assigned
  • Fujitsu XG2600 | Hardware Guide - Page 21
    XG2600 Hardware Guide Chapter 1 Getting Started LED Functions/Behaviors LED Name READY CHECK STATUS OUTFLOW State Green Green Blinking Off Orange Orange Blinking Off Green Green Blinking Off Green Off Status Switch has started up correctly. Switch is being diagnosed or operating under backup
  • Fujitsu XG2600 | Hardware Guide - Page 22
    XG2600 Hardware Guide 1.1.4 Switch Port Side PSU Slots for Rear-Access Installation Port1 SFP+ Slots Chapter 1 Getting Started Serial Port Reset Switch Port25 PSU1 Power Supply Unit Power Inlet Port2 PSU2 Power Supply Unit Port26 USB Port Management Port • PSU Slots for Rear-Access
  • Fujitsu XG2600 | Hardware Guide - Page 23
    XG2600 Hardware Guide slot. Indicates the operational state of the switch. Lights in orange when there is a problem. In this case, consult with responsible in green. That may cause to destroy configuration files. • ERROR LED • LINK/ACT LED • FDX LED There's a problem with USB memory or SFP+ modules,
  • Fujitsu XG2600 | Hardware Guide - Page 24
    firmware. (*) A problem occurs. A problem occurs which may require switch replacement. Firmware in the Flash memory of the switch is out of order. Switch is operating normally. PSU1 is in normal operation. PSU1 is not installed or PSU1 is installed incorrectly, causing configuration error. A problem
  • Fujitsu XG2600 | Hardware Guide - Page 25
    XG2600 Hardware Guide 1.1.5 Top Surface Chapter 1 Getting Started Rating Label • Warning Sticker • Rating Label Warning Sticker This indicates the warning for safety use. This indicates the rated voltage of the switch. 25 Items in the Package, Descriptions and Functions
  • Fujitsu XG2600 | Hardware Guide - Page 26
    XG2600 Hardware Guide 1.1.6 BOTTOM Surface Chapter 1 Getting Started Product Manufacturing Label • Product Manufacturing Label This indicates the model name, serial number, manufacturing date, and Class 1 Laser Product, etc. 26 Items in the Package, Descriptions and Functions
  • Fujitsu XG2600 | Hardware Guide - Page 27
    XG2600 Hardware Guide 1.2 Option 1.2.1 SFP+ Modules SFP+ modules (10GBASE-SR/10GBASE-LR) are available for use. "2.3.3 Connecting Twisted Pair Cable / SFP+ Module" (pg.46) Reference User's Guide " SFP+ Module" (pg.26) Chapter 1 Getting Started 27 Option
  • Fujitsu XG2600 | Hardware Guide - Page 28
    29 2.1.2 Space Requirements 30 2.2 Installation of the switch 31 2.2.1 Decide Switch Access Configuration 31 2.2.2 Rear-Access Configuration (Factory Default 35 2.2.3 Change Switch Access Configurations from Rear-Access (Factory Default) to FrontAccess and Install 38 2.3 Connecting the
  • Fujitsu XG2600 | Hardware Guide - Page 29
    XG2600 Hardware Guide Chapter 2 Installation 2.1 Requirements for Installation Environment Before installing the switch, please check the following: • Make sure that the switch and all the other options shown in this document are available for installation. • All the cables comply with the
  • Fujitsu XG2600 | Hardware Guide - Page 30
    XG2600 Hardware Guide Installation Requirements The product is specifically designed for rack-mounting. Check-list Check the following items. Check Item Nothing is put on the switch. Vents are not obstructed. The switch is not located on the table or not stuck on another switch. The switch is not
  • Fujitsu XG2600 | Hardware Guide - Page 31
    XG2600 Hardware Guide Chapter 2 Installation 2.2 Installation of the switch This section describes how to install the switch. 2.2.1 Decide Switch Access Configuration The switch is specifically designed for rack-mounting. The switch can be installed in two different switch access configurations (
  • Fujitsu XG2600 | Hardware Guide - Page 32
    XG2600 Hardware Guide Chapter 2 Installation Caution • Do not install PSUs to face the front side of the rack. They do not work properly. • Before installing the switch in the rack, check if the airflow direction of the fans is correct. If the air flows incorrectly, it may cause failure to the
  • Fujitsu XG2600 | Hardware Guide - Page 33
    XG2600 Hardware Guide Front-Access Configuration (User Configured) The port side (SFP+ slots) is facing forward in a rack. Chapter 2 Installation Exhaust Rack Rear PSU1 PSU2 FAN1 FAN2 (Caution) (Caution) Intake Rack Front XG2600 Caution • Do not install PSUs facing the front side of the
  • Fujitsu XG2600 | Hardware Guide - Page 34
    XG2600 Hardware Guide Chapter 2 Installation The diagram below shows in which slots PSUs need to be installed and airflow direction of the fans.  : Installing - : not installing Power Supply Unit Fan Unit Switch Port Side Switch Fan Unit Side FAN1 Slot FAN2 Slot PSU1 Slot - PSU2 Slot -
  • Fujitsu XG2600 | Hardware Guide - Page 35
    XG2600 Hardware Guide 2.2.2 Rear-Access Configuration (Factory Default) This section describes how to install switch in Rear-Access configuration (Factory Default). Chapter 2 Installation Decide positions for rack mounting brackets 1. Decide positions of rack mounting brackets. It is possible to
  • Fujitsu XG2600 | Hardware Guide - Page 36
    XG2600 Hardware Guide Install the switch in a 19" rack The switch can be installed and operated in the EIA standard 19" rack. Prepare the following rack mounting components attached. • Rack Mounting Rails (1 set): Rails for mounting the switch space for safe installation service. 1. Fix rack mounting
  • Fujitsu XG2600 | Hardware Guide - Page 37
    XG2600 Hardware Guide Chapter 2 Installation 2. Slide the switch between rails which are fixed to the rack, and fasten the 2 M6 screws to the front posts. M6 Machine Screws XG2600 M6 Machine Screws Precautions Pre-occupied devices in the upper and/or lower row of the rack may interfere with the
  • Fujitsu XG2600 | Hardware Guide - Page 38
    XG2600 Hardware Guide Chapter 2 Installation 2.2.3 Change Switch Access Configurations from Rear-Access (Factory Default) to Front-Access and Install This section describes how to change Rear-Access configuration (Factory Default) to Front-Access. Note For Front-Access configuration to Rear-
  • Fujitsu XG2600 | Hardware Guide - Page 39
    XG2600 Hardware Guide 1. Loosen two screws to remove fan unit. Chapter 2 Installation XG2600 Screw Screw 2. Remove fans (1) Remove two screws. (2) Unlock Cable Holder (which prevents cables from being pulled out). (3) Remove cables (3) (2) (1) 3. Change direction of fans. (1) Turn over
  • Fujitsu XG2600 | Hardware Guide - Page 40
    XG2600 Hardware Guide (2) Check if the direction shown in Airflow Label matches the airflow direction required. (3) Unlock Cable Holder to which the cable is pulled out. (3) (1) (2) 5. Insert back the Fan unit in the fan slot and fasten two screws to fix it to the switch. 40 Installation of the
  • Fujitsu XG2600 | Hardware Guide - Page 41
    XG2600 Hardware Guide Chapter 2 Installation Change PSU's positions to meet different switch access configurations There are two types of PSU Slot Bezel. • PSU Bezel (Vents with Logo) Put it to empty PSU1 slot. • PSU Bezel (Vents without Logo) Put
  • Fujitsu XG2600 | Hardware Guide - Page 42
    XG2600 Hardware Guide Chapter 2 Installation 3. Put PSU Bezel (Vents with Logo) to PSU1-slot on the Port Side with screws. Put PSU Bezel (Vents without Logo) to PSU2-slot right next to PSU1 slot with screws. XG2600 4. Slide PSUs into PSU1-slot and PSU2-slot and fix them to the switch with screws.
  • Fujitsu XG2600 | Hardware Guide - Page 43
    XG2600 Hardware Guide Chapter 2 Installation Attach rack mounting brackets to the switch 1. Attach rack mounting brackets to fit either a standard front position of the rack or a offset position of the rack. [STANDARD] XG2600 [OFFSET] Plug into the hole of the device. XG2600 Rack Mounting
  • Fujitsu XG2600 | Hardware Guide - Page 44
    XG2600 Hardware Guide Chapter 2 Installation 2.3 Connecting the Equipment We recommend discharging static electricity of twisted pair cable before connecting it to the switch. Also see below for how to install USB memory. 2.3.1 Discharging Twisted Pair Cable Discharge static electricity of the
  • Fujitsu XG2600 | Hardware Guide - Page 45
    XG2600 Hardware Guide Cleaning of Optical Connector Chapter 2 Installation 1. Remove the be completely wiped off and more dust may adhere. • Immediately connect optical connector to the switch after cleaning. Dust will adhere when the optical connector is left unconnected. • Keep the connector
  • Fujitsu XG2600 | Hardware Guide - Page 46
    XG2600 Hardware Guide Chapter 2 Installation 2.3.3 Connecting Twisted Pair Cable / SFP+ Module Below is how to connect twisted pair cable and SFP+ module. Use the crossover cable when connecting with routers and terminals. Use the straight cable in case of cascading connection with other switching
  • Fujitsu XG2600 | Hardware Guide - Page 47
    XG2600 Hardware Guide Connecting SFP+ Module Firmly install SFP+ module to SFP+ slot and lock module to the switch. SFP+ module Chapter 2 Insert SFP+ module to the SFP+ slot, and lock the module and the switch. Connect optical cable (connector shape: DLC) after inserting SFP+ module to the
  • Fujitsu XG2600 | Hardware Guide - Page 48
    XG2600 Hardware Guide Chapter 2 Installation Precautions Cable length will be as below based on the specification of the optical fiber cable. Type MMF Core/Cladding Diameter 62.5/125µm 50/125µm Minimum Transimission Band Cable Length (m) 160MHz/km 26 200MHz/km 33 400MHz/km 66 500MHz/km
  • Fujitsu XG2600 | Hardware Guide - Page 49
    XG2600 Hardware Guide Chapter 2 Installation 3. Connect optical cable and release the "disable status" of the SFP+ slot. • In case of using telnet or console Enter replacing SFP+ slot number in # online ether • In case of using www browser Make the SFP+ slot number at the selective
  • Fujitsu XG2600 | Hardware Guide - Page 50
    XG2600 Hardware Guide Chapter 2 Installation 2.3.4 Plugging in the USB Memory USB memory can be plugged in from the port side of the switch. Caution Do NOT unplug out the memory stick during access. It may result in crashing setting data. Precautions It is possible to plug/unplug SFP+
  • Fujitsu XG2600 | Hardware Guide - Page 51
    XG2600 Hardware Guide 2.4 Connecting a Setup PC This is to connect a set up PC to the console port of the switch using RS232C cable. Chapter 2 Installation Necessary Hardware / Software Please prepare the hardware & software specified below to connect to the switch. • Personal Computer 1 unit of
  • Fujitsu XG2600 | Hardware Guide - Page 52
    XG2600 Hardware Guide Turn on the Power Chapter 2 Installation Caution • Please use , delete the error log using the console command after turning on the power of the switch. # clear logging error # Reference User's Guide "5.18.1.5 clear logging error" (pg.365) • When turning off the power. Please
  • Fujitsu XG2600 | Hardware Guide - Page 53
    XG2600 Hardware Guide 3. POWER LED of PSU1 and PSU1 LED of the switch will light in green. Next, plug in the power cable to the power connecter of PSU2. The POWER LED of PSU2 and PSU2 LED of the switch Please refer to the terminal software manual for instructions on setting conditions. 3. Press [
  • Fujitsu XG2600 | Hardware Guide - Page 54
    XG2600 Hardware Guide Chapter 2 Installation 8. Confirm "#" is shown on screen. If the key in the wrong password, "invalid password." will be displayed, then the "Login :" will be displayed again. Please repeat your process from item 5. 54 Connecting a Setup PC
  • Fujitsu XG2600 | Hardware Guide - Page 55
    XG2600 Hardware Guide Chapter 2 Installation 2.5 Time Setting Make sure to set up the time before you do other settings of the switch. The time is not set at the initial timing of purchase. Please refer below command for setting up time manually using console or telnet. z Command When setting
  • Fujitsu XG2600 | Hardware Guide - Page 56
    XG2600 Hardware Guide Chapter 2 Installation 2.6 Set up IP address Please set the IP address at times when it is required. Eg. When setting the switch through www browser or installing a firmware from the initial state of the purchase. The following commands show how to set up the IP address (ex.
  • Fujitsu XG2600 | Hardware Guide - Page 57
    XG2600 Hardware Guide Index B BOTTOM Surface 26 C CD-ROM 19 CHECK LED 20, 23 Communication Software 51 Connecting the Equipment 44 Console cable adapter 18 Console port 51 E ERROR LED 23 F FAN LED 23 Fan Unit 20 FDX LED 23 FLASH LED 23 Front-Access Configuration 33 H Hardware 51 I
  • Fujitsu XG2600 | Hardware Guide - Page 58
    XG2600 Hardware Guide Index U USB Memory 50 USB Port 22 W Warning Sticker 25 58
  • Fujitsu XG2600 | Hardware Guide - Page 59
    XG2600 Hardware Guide TA41001-7426 Issued on February, 2011 Issued by FUJITSU LIMITED Printed in Japan • The contents may be revised without prior notice. • Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. • No
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59

Hardware Guide
TA41001-7426
XG2600 Hardware Guide
Introduction