GE DSXH47EGWW Owners Manual - Page 15

Mobile Home Installation, Rough-in Dimensions

Page 15 highlights

Installation Instructions MOBILE HOME INSTALLATION 1. Dryer MUST be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4″ (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. 2. If the dryer is exhausted through the floor, the exhaust system MUST NOT terminate beneath the mobile home. Termination MUST be securely fastened to the mobile home structure. 3. When installing a gas dryer into a mobile home, a provision must be made for outside make-up air. This provision is to be not less than twice the area of the dryer exhaust outlet. 4. Gas dryers MUST be fastened to the floor using Mobile Home Installation Kit Pub. No. 14-D346-33. 5. See the Exhaust System Checklist section for other important venting information. 6. Installation MUST conform to current Manufactured Home Construction & Safety Standard (which is a Federal Regulation Title 24 CFR-Part 32-80) or, when such standard is not applicable, with American National Standard for Mobile Homes, ANSI/NFPA No. 501B. Correct Do ROUGH-IN DIMENSIONS Electrical supply on rear of unit 2 1/4″ (5.7 cm) Gas supply pipe on rear of unit 36″ (91.4 cm) 13 1/2″ 2 3/8″ (34.3 cm) (6.03 cm) To rear and base exhausts 27″ (68.6 cm) FRONT VIEW 48 1/2″ (123.2 cm) to clear open door Incorrect Don't Don't Don't The dryer is designed under ANSI Z 21.5.1. 5″ (12.7 cm) Center line height for rear, right, left vent 28 1/2″ (72.4 cm) 4 3/8″ (11.1 cm) to side exhausts 5 7/8″ (14.9 cm) to base exhaust 27 1/4″ (69.2 cm) to front of cabinet 27 3/4″ (70.5 cm) to clear knobs 28 1/2″ (72.4 cm) to clear door handle SIDE VIEW SERVICING - Consideration must be given to provide adequate clearances for installation and servicing. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Installation Instructions
15
MOBILE HOME INSTALLATION
1.
Dryer
MUST
be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting that will
not support combustion. Metal ducting must be 4
(10.16 cm) in diameter with no obstructions. Rigid metal
duct is preferred.
2.
If the dryer is exhausted through the floor, the exhaust
system
MUST NOT
terminate beneath the mobile
home. Termination
MUST
be securely fastened to the
mobile home structure.
3.
When installing a gas dryer into a mobile home, a
provision must be made for outside make-up air. This
provision is to be not less than twice the area of the dryer
exhaust outlet.
4.
Gas dryers
MUST
be fastened to the floor using Mobile
Home Installation Kit Pub. No. 14–D346–33.
5.
See the
Exhaust System Checklist
section for other
important venting information.
6.
Installation
MUST
conform to current Manufactured
Home Construction & Safety Standard (which is a
Federal Regulation Title 24 CFR—Part 32–80) or,
when such standard is not applicable, with American
National Standard for Mobile Homes, ANSI/NFPA No.
501B.
The dryer is designed under ANSI Z 21.5.1.
Correct
Incorrect
Do
Don’t
Don’t
Don’t
ROUGH-IN DIMENSIONS
48 1/2
(123.2 cm)
to clear open door
27 1/4
(69.2 cm) to front of cabinet
27 3/4
(70.5 cm) to clear knobs
28 1/2
(72.4 cm) to clear door handle
SIDE VIEW
36
(91.4 cm)
Electrical supply
on rear of unit
FRONT VIEW
SERVICING –
Consideration must be given to provide
adequate clearances for installation and servicing.
2 3/8
(6.03 cm)
2 1/4
(5.7 cm)
Gas supply pipe
on rear of unit
4 3/8
(11.1 cm)
to side exhausts
5 7/8
(14.9 cm)
to base exhaust
28 1/2
(72.4 cm)
5
(12.7 cm)
Center line
height for rear,
right, left vent
13 1/2
(34.3 cm)
To rear and base exhausts
27
(68.6 cm)