GE GSM2260VSS Installation Instructions - Page 5

Installation Preparation-Electrical Supply - model

Page 5 highlights

Installation Preparation-Electrical Supply PREPARE ELECTRICAL WIRING WARNING FOR PERSONAL SAFETY: Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. 18" 18" 1-1/2" Dia. Hole (Max.) 5" 4" 5" 4" Alternate Receptacle Location ADVERTENCIA #282 French PARA SEGURIDAD PERSONAL: Retire el fusible de la casa o abra el interruptor de circuitos antes de empezar la instalación. No use un cable de extensión o enchufe adaptador con este aparato. Electrical Requirements • This appliance must be supplied with 120V, 60 Hz., and ­c­ onnected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. • Wiring must be 2 wire with ground. • If the electrical supply does not meet the above ­requirements, call a licensed electrician before ­proceeding. Grounding Instructions-Permanent Connection This appliance must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal or lead on the appliance. Grounding Instructions-Power Cord Models This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances. WARNING The improper connection of the e­­ quipment grounding conductor can result in electric shock. Check with a qualified electrician or service representative if you are in doubt that the appliance is properly grounded. Do not modify the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified technician. ADVERTENCIA #282 French La conexión incorrecta del conductor de conexión a tierra del equipo puede resultar en choque eléctrico. Consulte con un electricista calificado o representante de servicio si tiene dudas de la conexión a tierra del aparato. No modifique el enchufe que se suministra con el aparato; si no calza en el tomacorrientes, haga que un técnico calificado le instale un tomacorrientes adecuado. 6" Figure E 6" Receptacle Location Area 3" 6"Cafrboimnet 24" from Wall Ground Black White Cabinet Preparation & Wire Routing • The wiring may enter the opening from either side, rear, or floor within the shaded area illustrated above in Figure E. • Cut a 1-1/2" maximum diameter hole to insert the electrical cable. Permanent wiring connections 679DiaC may pass through the same hole as the drain hose and hot water line, if convenient. Hole edges must be smooth and rounded. If the cabinet wall is metal, the hole edge must be covered with a cord protector. NOTE: Power cords with plug must pass through a separate hole. Metal Cabinet Wall Cord Protector Hole Diameter 1-1/2" Maximum Electrical Connection to Dishwasher Electrical connection is on the right front of dishwasher. • For permanent connections, the cable must be routed as shown in Figure E. The cable must extend a minimum of 24" from the rear wall. • For power cord connections, install a 3-prong grounding type receptacle in the adjacent cabinet rear wall, between 6" and 18" from the opening, 6" to 18" above the floor as shown in Figure E. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

The improper connection of the equipment
grounding conductor can result in electric
shock. Check with a qualified electrician or
service representative if you are in doubt
that the appliance is properly grounded.
Do not modify the plug provided with the
appliance; if it will not fit the outlet, have
a proper outlet installed by a qualified
technician.
WARNING
5
Cabinet Preparation & Wire Routing
• The wiring may enter the opening from either side,
rear, or floor within the shaded area illustrated
above in Figure E.
• Cut a 1-1/2" maximum diameter hole to insert the
electrical cable. Permanent wiring connections
may pass through the same hole as the drain
hose and hot water line, if convenient. Hole edges
must be smooth and rounded. If the cabinet wall is
metal, the hole edge must be covered with a cord
protector.
NOTE:
Power cords with plug must pass through a
separate hole.
PREPARE ELECTRICAL WIRING
Electrical Requirements
• This appliance must be supplied with 120V, 60 Hz.,
and connected to an individual properly grounded
branch circuit, protected by a 15 or 20 ampere
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
Grounding Instructions–Permanent Connection
This appliance must be connected to a grounded
metal, permanent wiring system, or an equipment
grounding conductor must be run with the circuit
conductors and be connected to the equipment
grounding terminal or lead on the appliance.
Grounding Instructions–Power Cord Models
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce
the risk of electric shock by providing a path of
least resistance for electric current. This appliance
is equipped with a cord having an equipment
grounding conductor and a grounding plug. The plug
must be plugged into an appropriate outlet that is
installed and grounded in accordance with all local
codes and ordinances.
Figure E
Installation Preparation–Electrical Supply
WARNING
FOR PERSONAL SAFETY: Remove house
fuse or open circuit breaker before
beginning installation. Do not use an
extension cord or adapter plug with this
appliance.
Electrical Connection to Dishwasher
Electrical connection is on the right front of
dishwasher.
• For permanent connections, the cable must be
routed as shown in Figure E. The cable must extend
a minimum of 24" from the rear wall.
• For power cord connections, install a 3-prong
grounding type receptacle in the adjacent cabinet
rear wall, between 6" and 18" from the opening, 6"
to 18" above the floor as shown in Figure E.
Hole Diameter
1-1/2" Maximum
Cord
Protector
Metal Cabinet Wall
5"
White
18"
6"
5"
4"
4"
24"
from Wall
3"
from
Cabinet
Alternate
Receptacle
Location
Ground
Black
1-1/2" Dia.
Hole (Max.)
18"
6"
6"
Receptacle
Location
Area
ADVERTENCIA
La conexión incorrecta del conductor de
conexión a tierra del equipo puede resultar en
choque eléctrico. Consulte con un electricista
calificado o representante de servicio si tiene
dudas de la conexión a tierra del aparato. No
modifique el enchufe que se suministra con
el aparato; si no calza en el tomacorrientes,
haga que un técnico calificado le instale un
tomacorrientes adecuado.
ADVERTENCIA
PARA SEGURIDAD PERSONAL: Retire el fusible
de la casa o abra el interruptor de circuitos
antes de empezar la instalación. No use un
cable de extensión o enchufe adaptador con
este aparato.