LP Conversion Instructions GAS SUPPLY • With the installation of this conversion kit, the cooktop should operate on LP gas at 10″ of water column pressure. • The pressure regulator must be connected in series with the manifold of the cooktop and must remain in series with the supply line. For proper operation, the maximum inlet pressure to the regulator must be no more than 14″ water column pressure for LP gas. • When checking the regulator, the inlet pressure must be at least 1″ greater than the regulator output setting. If the regulator is set for 10″ of water column pressure, the inlet pressure must be at least 11″. IMPORTANT - Disconnect the cooktop and the individual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig. Isolate the cooktop from the gas supply piping system by closing the individual manual shut-off valve to the cooktop during any pressure testing of the gas supply piping system at test pressures equal to or greater than 1/2 psig. TURN OFF GAS AND ELECTRIC SUPPLY BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT THE SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL SUPPLY FROM THE COOKTOP. 1 CONVERT THE PRESSURE REGULATOR A Locate the pressure regulator under the front of the cooktop. B Remove the nut from the pressure regulator with an adjustable wrench. Natural gas Nut LP gas C Remove the plastic pin from the inside of the nut, turn the pin 180° and snap the pin back into the nut. Natural gas LP gas Nut Shut-off valve Electrical supply D Re-install the nut onto the regulator. E Apply the LP Conversion label next to the Rating Plate. 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

31
LP Conversion Instructions
With the installation of this conversion kit,
the cooktop should operate on LP gas at 10
of water column pressure.
The pressure regulator must be connected in series
with the manifold of the cooktop and must remain
in series with the supply line. For proper operation,
the maximum inlet pressure to the regulator must
be no more than 14
water column pressure for
LP gas.
When checking the regulator, the inlet pressure
must be at least 1
greater than the regulator output
setting. If the regulator is set for 10
of water column
pressure, the inlet pressure must be at least 11.
IMPORTANT –
Disconnect the cooktop and
the individual shut-off valve from the gas supply piping
system during any pressure testing of that system at test
pressures greater than 1/2 psig. Isolate the cooktop from
the gas supply piping system by closing the individual
manual shut-off valve to the cooktop during any pressure
testing of the gas supply piping system at test pressures
equal to or greater than 1/2 psig.
GAS SUPPLY
BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT
THE SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL
SUPPLY FROM THE COOKTOP.
TURN OFF GAS AND
ELECTRIC SUPPLY
CONVERT THE PRESSURE REGULATOR
Locate the pressure regulator under the front
of the cooktop.
A
1
Remove the nut from the pressure regulator with
an adjustable wrench.
B
Remove the plastic pin from the inside of the nut,
turn the pin 180° and snap the pin back into the nut.
C
Re-install the nut onto the regulator.
Apply the LP Conversion label next to the Rating Plate.
E
D
Shut-off valve
Electrical supply
Nut
Natural gas
LP gas
Nut
Natural gas
LP gas