GE JN328KSA Installation Instructions - Page 13
Mark Holes, Cut Holes, Run Wires
![]() |
View all GE JN328KSA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
INSTALLATION INSTRUCTIONS Installation Instructions 11 MARK HOLES Select the vent option that your installation will require and proceed to that section: A Outside top exhaust (Vertical duct-3-1/4" x 10" Rectangular) Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots. Hood mounting screws (4) 103ø4s (24s hood) 133ø4s (30s hood) 163ø4s (36s hood) Cabinet front 103ø4s (24s hood) 133ø4s (30s hood) 163ø4s (36s hood) 33ø4s 1ø2s 73ø4s Cabinet Bottom 51ø4s 51ø4s Vertical duct access hole 11ø4s 95ø8s 13ø8s Electrical access hole Wood shims (recessed-bottom Center (in cabinet bottom) cabinets only-shims line must be a minimum of 3/8s thick and cut to fit the width of the inner recessed cabinet bottom) B Outside top exhaust (Vertical duct-7" Round) Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots. Hood mounting screws (4) 103ø4s (24s hood) 133ø4s (30s hood) 163ø4s (36s hood) Cabinet front 103ø4s (24s hood) 133ø4s (30s hood) 163ø4s (36s hood) Cabinet bottom Access hole for 7s round duct 73ø4s 8s DIA. HOLE 53ø4s 11ø4s 95ø8s 13ø8s Wood shims (recessedbottom cabinets only-shims Center must be a minimum of 3/8s line thick and cut to fit the width of the inner recessed cabinet bottom) Electrical access hole (in cabinet bottom) 49-80589-6 C Outside rear exhaust (Horizontal duct-3-1/4" x 10" Rectangular) Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots. Wood shims (recessed-bottom cabinets only-shims must be a minimum of 3/8s thick and cut to fit the width of the inner recessed cabinet bottom) Cabinet front 1ø2s 11ø4s 33ø4s Cabinet bottom Horizontal duct access hole 51ø4s 51ø4s 73ø4s 103ø4s (24s hood) 103ø4s (24s hood) 133ø4s (30s hood) 133ø4s (30s hood) 163ø4s (36s hood) 163ø4s (36s hood) Hood mounting screws (4) Center line Electrical access hole (in wall) D Recirculating (non-vented ductless- JN327, JN328 and RN328, and optional on JV247, JV248, JV347, JV348, JV367 and AV447 models only) • Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots. • Since the hood is to be recirculated (not to be vented outside), do not cut out any vent openings in the wall or cabinet bottom. 12 CUT HOLES Cut holes at marked locations for duct and electrical wiring. For the vertical duct, cut out ƎH[WUDWRZDUGWKHIURQWRIWKHFDELQHWVR you can move the duct freely when installing the hood. It may also ease installation by FXWWLQJWKHKROH»ƎLQVWHDGRIƎ 13 RUN WIRES Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes. NOTE: DO NOT turn the power on until installation is complete. 13
![](/manual_guide/products/general-electric-jn328ksa-installation-instructions-197b0d0/13.png)