Haier HBF05EBSS Product Manual - Page 20
Keg Connections
UPC - 688057300108
View all Haier HBF05EBSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
English KEG CONNECTIONS How do I replace an empty CO2 tank? 1. Close tank drum valve by turning clockwise. 2. Unscrew adjustment Set Screw (counter-clockwise) as far as it will go and close shut off valve. 3. Remove regulator from empty tank. 4. Remove dust cap from the new full tank. Open and close drum valve quickly to blow of the dust from the outlet. 5. With drum valve in closed position, reattach regulator to the tank. Be sure to check the washer, which is pre-installed on the CO2 regulator. 6. Open drum valve all the way. (This is important because this drum valve seals in two places.) 7. Readjust regulator pressure by turning set screw and open shut off valve. Tank Information: Tank must always be fastened in the upright position. It takes about 1/2 lb. of CO2 to dispense 1/2 barrel keg of beer. A 5 lb. CO2 tank should dispense between 8-10 1/2 barrel kegs or 18-20 1/4 barrel kegs. Full weight of 5 lb. tank is appx. 17-1/2 lbs. 19