Part A - 4-wire Power Cord
![]() |
View all Haier HLTD500AGW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Tab A Strain Relief B 3. Insert a power cord into the strain relief. Take care to ensure that the wire insulation of the power cord is inside the strain relief. 4. Connect power cord wires following Part A for a 4-wire power cord connection or Part B for a 3-wire power cord connection. 4-wire (recommended) if your home has a 4-wire receptacle (NEMA 14-30 type SRDT or ST): 3-wire (if 4-wire is not available) if your home has a 3-wire receptacle (NEMA 10-30 type SRDT): CAUTION: A 4-conductor cord shall be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors. 5. Tighten strain relief screws. 6. Be sure that none of the wires are touching the dryer drum inside the dryer cabinet. 7. Reinstall the terminal block cover. PART A - 4-WIRE POWER CORD A B C D E F Ground Screw (Green) Terminal Block Screw Neutral-Ground Jumper Wire (Green) Power Cord Ground Wire (Green) G Power Cord Neutral Wire (White) Power Cord Line Wires (One Red; One Black) Power Cord 17