Haier HLTD500AGW User Manual - Page 20
Part B - 3-wire Power Cord
![]() |
View all Haier HLTD500AGW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
A1. Remove the green ground screw connecting the neutral-ground jumper wire (green) to the cabinet and the center terminal block screw, then discard the jumper wire. A2. Attach the power cord ground wire (green) to the cabinet with the green ground screw. Tighten the screw securely. A3. Attach the power cord neutral wire (white) with the center terminal block screw. Tighten the screw securely. A4. Attach the remaining 2 power cord line wires (red and black) with the outer terminal block screws. Attach one wire to each terminal block as shown. Tighten both screws securely. IMPORTANT: Do not make a sharp bend or crimp the wires at connections. PART B - 3-WIRE POWER CORD A B C D E F Ground Screw (Green) Power Cord Neutral Wire (White) Terminal Block Screw Neutral-Ground Jumper Wire (Green) Power Cord Line Wires (One Red; One Black) Power Cord B1. Attach the power cord neutral wire (white) to the center terminal block screw. Tighten the screw securely. B2. Attach the remaining 2 power cord line wires (red and black) with the outer terminal block screws. Attach one wire to each terminal block as shown. Tighten both screws securely. IMPORTANT: Do not make a sharp bend or crimp the wires at connections. 18
![](/manual_guide/products/haier-hltd500aew-user-manual-54b785c/20.png)