Harman Kardon AVR80MKII Owners Manual - Page 36

Return, Menu., Select., Variable, Fixed., Level., Multi

Page 36 highlights

Multiroom Operation 34 3. When the source is selected, press the y button until the > cursor is next to RETURN TO MAIN MENU. Press SELECT. 4. At the MAIN MENU, press the button once so that the > cursor is pointing to SET UP MENU. Press SELECT. 5. This will bring SET UP MENU 1 (Figure #2) to the screen. Press the y button twice until the > cursor is pointing to GO TO SET UP MENU 2. Press SELECT. 6. When SET UP MENU 2 (Figure #3) appears, the > cursor will be pointingtoMULTI Rti VOL.Usethel or buttons 41) on the remote to select one of the following choices. a. If the remote room is equipped with a remote receiver only, volume control will be performed by the AVR80ii using a remote control in the second room. For this type of control, select the VARIABLE option. b. If the volume control in the remote room will be controlled by the amplifier in the remote room, or if a specialized amplifier such as the AudioAccess AVX-603 will be used, select FIXED. 7. After making a selection, press the y button once so that the > cursor is next to SET LEVEL. 8. Use the 1 or buttons (le on the remote to establish a volume level for turn on or constant level, as determined by the previous selection. a. If VARIABLEvolume has been selected, this setting will determine the volume level for the remote room each time it is turned on. b. If FIXED volume has been selected, this level will be the constant volume level at the remote room location unless a local volume control is installed. Set the level as close to "0 dB" as possible without distorting the output signal. 9. When the level has been entered, press the y button so that the > cursor is pointing to RETURN TO MAIN MENU and press SELECT. 10. At the MAIN MENU, use the navigational arrow buttons on the remote to exit from the main system. The AVR80ii is now configured for multi room operation. Operation Multi room operation is simple, and it may be controlled from either the main listening room where the AVR80ii is located, or from a remote room where an IR receiver or AudioAccess keypad has been installed. Main Room Operation In this option, the remote room feed is controlled from the main listening room using the AVR80irs front panel controls. To activate the remote room feed, press the MULTI button on the front panel D. This will send the signal of the AVR80irs currently selected input source to the remote room at the volume level established in SET UP MENU 2. MULTI ROOM SELECTOR >SELECTED:TUNER CD TAPE1 OFF TAPE2 TV LD VCR1 VCR2 AUX RETURN TO MAIN MENU Figure 17 TURN MULTI -ZONE OFF? USERS MAY BE LISTENING IN OTHER ROOMS PRESS AGAIN TO PROCEED OR "CLEAR" TO CANCEL Figure 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39

Multiroom
Operation
34
3.
When
the
source
is
selected,
press
the
y
button
until
the
>
cursor
is
next
to
RETURN
TO
MAIN
MENU.
Press
SELECT.
4.
At
the
MAIN
MENU,
press
the
button
once
so
that
the
>
cursor
is
point-
ing
to
SET
UP
MENU.
Press
SELECT.
5.
This
will
bring
SET
UP
MENU
1
(Figure
#2)
to
the
screen.
Press
the
y
button
twice
until
the
>
cursor
is
point-
ing
to
GO
TO
SET
UP
MENU
2.
Press
SELECT.
6.
When
SET
UP
MENU
2
(Figure
#3)
appears,
the
>
cursor
will
be
point-
ingtoMULTI
Rti
VOL.Usethel
or
buttons
41)
on
the
remote
to
select
one
of
the
following
choices.
a.
If
the
remote
room
is
equipped
with
a
remote
receiver
only,
volume
control
will
be
performed
by
the
AVR80ii
using
a
remote
control
in
the
second
room.
For
this
type
of
control,
select
the
VARIABLE
option.
b.
If
the
volume
control
in
the
remote
room
will
be
controlled
by
the
ampli-
fier
in
the
remote
room,
or
if
a
spe-
cialized
amplifier
such
as
the
AudioAccess
AVX-603
will
be
used,
select
FIXED.
7.
After
making
a
selection,
press
the
y
button
once
so
that
the
>
cursor
is
next
to
SET
LEVEL.
8.
Use
the
1
or
buttons
(le
on
the
remote
to
establish
a
volume
level
for
turn
on
or
constant
level,
as
determined
by
the
previous
selection.
a.
If
VARIABLEvolume
has
been
selected,
this
setting
will
determine
the
volume
level
for
the
remote
room
each
time
it
is
turned
on.
b.
If
FIXED
volume
has
been
select-
ed,
this
level
will
be
the
constant
vol-
ume
level
at
the
remote
room
location
unless
a
local
volume
con-
trol
is
installed.
Set
the
level
as
close
to
"0
dB"
as
possible
without
distort-
ing
the
output
signal.
9.
When
the
level
has
been
entered,
press
the
y
button
so
that
the
>
cursor
is
pointing
to
RETURN
TO
MAIN
MENU
and
press
SELECT.
10.
At
the
MAIN
MENU,
use
the
navi-
gational
arrow
buttons
on
the
remote
to
exit
from
the
main
system.
The
AVR80ii
is
now
configured
for
multi
room
operation.
Operation
Multi
room
operation
is
simple,
and
it
may
be
controlled
from
either
the
main
listening
room
where
the
AVR80ii
is
located,
or
from
a
remote
room
where
an
IR
receiver
or
AudioAccess
keypad
has
been
installed.
Main
Room
Operation
In
this
option,
the
remote
room
feed
is
controlled
from
the
main
listening
room
using
the
AVR80irs
front
panel
controls.
To
activate
the
remote
room
feed,
press
the
MULTI
button
on
the
front
panel
D.
This
will
send
the
signal
of
the
AVR80irs
currently
selected
input
source
to
the
remote
room
at
the
volume
level
estab-
lished
in
SET
UP
MENU
2.
MULTI
ROOM
SELECTOR
>SELECTED:TUNER
CD
TAPE1
OFF
TAPE2
TV
LD
VCR1
VCR2
AUX
RETURN
TO
MAIN
MENU
Figure
17
TURN
MULTI -ZONE
OFF?
USERS
MAY
BE
LISTENING
IN
OTHER
ROOMS
PRESS
AGAIN
TO
PROCEED
OR
"CLEAR"
TO
CANCEL
Figure
18