Specifications, Table A-1 - tower

Page 50 highlights

A Specifications Table A-1 Specifications Desktop Dimensions Height 7.0 in 17.78 cm Width 17.63 in 44.78 cm Depth 17.5 in 44.45 cm Tower Dimensions Height 17.63 in 44.78 cm Width 7.0 in 17.78 cm Depth 17.5 in 44.45 cm Approximate Weight 24.54 lb 11.15 kg Weight Supported (maximum distributed load in desktop position) 77 lb 35 kg Temperature Range Operating 50° to 95°F 10° to 35°C Nonoperating -22° to 140°F -30° to 60°C NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed. Relative Humidity (noncondensing) Operating 10-90% 10-90% Nonoperating (38.7°C max wet bulb) 5-95% 5-95% Maximum Altitude (unpressurized) Operating 10,000 ft 3048 m Nonoperating 30,000 ft 9144 m Heat Dissipation Max STD PS 1410 BTU/hr 356 kg-cal/hr Typical STD PS idle 222 BTU/hr 56 kg-cal/hr Max EPA 87/89/85% @ 20/50/100% load PS 1255 BTU/hr 316 kg-cal/hr Typical EPA 87/89/85% @ 20/50/100% load PS idle 171 BTU/hr 43 kg-cal/hr 44 Appendix A Specifications ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

A
Specifications
Table A-1
Specifications
Desktop Dimensions
Height
Width
Depth
7.0 in
17.63 in
17.5 in
17.78 cm
44.78 cm
44.45 cm
Tower Dimensions
Height
Width
Depth
17.63 in
7.0 in
17.5 in
44.78 cm
17.78 cm
44.45 cm
Approximate Weight
24.54 lb
11.15 kg
Weight Supported
(maximum distributed load in desktop
position)
77 lb
35 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
NOTE:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct
sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of
options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
Heat Dissipation
Max STD PS
Typical STD PS idle
Max EPA 87/89/85% @ 20/50/100% load PS
Typical EPA 87/89/85% @ 20/50/100% load PS idle
1410 BTU/hr
222 BTU/hr
1255 BTU/hr
171 BTU/hr
356 kg-cal/hr
56 kg-cal/hr
316 kg-cal/hr
43 kg-cal/hr
44
Appendix A
Specifications
ENWW