Audible Beeps: None Possible Cause: The controller or firmware version does not support the attached drive enclosure. Action: Upgrade the controller or detach the expander-based storage connections. 1747-Slot z Drive Array - Unsupported Array Configuration Detected... ...Followed by one of many possible reasons, including the following: * More logical drives are configured than this controller can support when the memory module is detached. * One or more logical drives are configured in positions that this controller does not support when the memory module is detached. * One or more logical drives are configured for RAID fault tolerance level(s) that are not supported when the memory module is detached. * Configuration information indicates one or more hard drives are located in drive bays that are inaccessible when the memory module is detached. * Capacity Expansion operations are pending but cannot continue because the Array Accelerator memory module has been detached. * Drive Erase operations are pending but cannot be completed because the Array Accelerator memory module has been detached. ALL logical drives have been disabled. To avoid data loss, re-attach drives to original controller or upgrade controller. To discard all data and create a new configuration, run the Array Configuration Utility. Audible Beeps: None Possible Causes: • The Array Accelerator memory module was removed or is defective. • The drives were moved to a controller that does not have an Array Accelerator memory module attached. Action: Attach an Array Accelerator memory module to this controller, or move the drives back to the original controller. If Capacity Expansion operations were pending, be sure that the original Array Accelerator module is attached. 1748-Slot X Drive Array - Unsupported Array Accelerator Battery Attached... ...Please install battery pack(s) with the correct part number. Audible Beeps: None Possible Cause: The current battery pack is not supported on this Array Accelerator module. Action: Install only supported battery packs with the correct part number. 1753-Slot Z Drive Array - Array Controller Maximum Operating Temperature Exceeded During Previous Power Up Audible Beeps: None Possible Cause: Controller is overheating. Action: Be sure adequate system cooling and sufficient airflow across controller are available. Error messages 145
-
1
-
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
-
10
-
11
-
12
-
13
-
14
-
15
-
16
-
17
-
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
-
26
-
27
-
28
-
29
-
30
-
31
-
32
-
33
-
34
-
35
-
36
-
37
-
38
-
39
-
40
-
41
-
42
-
43
-
44
-
45
-
46
-
47
-
48
-
49
-
50
-
51
-
52
-
53
-
54
-
55
-
56
-
57
-
58
-
59
-
60
-
61
-
62
-
63
-
64
-
65
-
66
-
67
-
68
-
69
-
70
-
71
-
72
-
73
-
74
-
75
-
76
-
77
-
78
-
79
-
80
-
81
-
82
-
83
-
84
-
85
-
86
-
87
-
88
-
89
-
90
-
91
-
92
-
93
-
94
-
95
-
96
-
97
-
98
-
99
-
100
-
101
-
102
-
103
-
104
-
105
-
106
-
107
-
108
-
109
-
110
-
111
-
112
-
113
-
114
-
115
-
116
-
117
-
118
-
119
-
120
-
121
-
122
-
123
-
124
-
125
-
126
-
127
-
128
-
129
-
130
-
131
-
132
-
133
-
134
-
135
-
136
-
137
-
138
-
139
-
140
-
141
-
142
-
143
-
144
-
145
-
146
-
147
-
148
-
149
-
150
-
151
-
152
-
153
-
154
-
155
-
156
-
157
-
158
-
159
-
160
-
161
-
162
-
163
-
164
-
165
-
166
-
167
-
168
-
169
-
170
-
171
-
172
-
173
-
174
-
175
-
176
-
177
-
178
-
179
-
180
-
181
-
182
-
183
-
184
-
185
-
186
-
187
-
188