HP BL2x220c HP ProLiant Servers Troubleshooting Guide - Page 98
Logical Drive X Failed Due to Cache Error
View all HP BL2x220c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
Identify Logical Drive Data did not Match with NVRAM Description: The identify unit data from the array controller does not match with the information stored in NVRAM. This can occur if new, previously configured drives have been placed in a system that has also been previously configured. Action: Run the server setup utility to configure the controller and NVRAM. Insufficient adapter resources Description: The adapter does not have sufficient resources to perform posted-write operations to the array accelerator board. Drive rebuild may be occurring. Action: Operate the system without the array accelerator board until the drive rebuild completes. Inter-Controller Link Connection Could Not Be Established Description: Unable to communicate over the link connecting the redundant controllers. Action: Be sure both controllers are using the same hardware and firmware revisions. If one controller failed, replace it. Less Than 75% Batteries at Sufficient Voltage Description: The operation of the array accelerator board has been disabled due to less than 75% of the battery packs being at the sufficient voltage level. Action: Replace the array accelerator board if the batteries do not recharge within 36 powered-on hours. Less Than 75% of Batteries at Sufficient Voltage Battery Pack X Below Reference Voltage Description: Battery pack on the array accelerator is below the required voltage levels. Action: Replace the array accelerator board if the batteries do not recharge within 36 powered-on hours. Logical Drive X Failed Due to Cache Error Description: This logical drive failed due to a catastrophic cache error. Action: Replace the array accelerator board and reconfigure using ACU ("Array Configuration Utility" on page 67). Logical Drive X Status = Failed Description: This status could be issued for several reasons: • Logical drive is configured for No Fault Tolerance, and one or more drives failed. • Mirroring is enabled, and any two mirrored drives failed. • Data Guarding is enabled, and two or more drives failed. • Another configured logical drive is in the WRONG DRIVE REPLACED or LOOSE CABLE DETECTED state. Error messages 98
-
1
-
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
-
10
-
11
-
12
-
13
-
14
-
15
-
16
-
17
-
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
-
26
-
27
-
28
-
29
-
30
-
31
-
32
-
33
-
34
-
35
-
36
-
37
-
38
-
39
-
40
-
41
-
42
-
43
-
44
-
45
-
46
-
47
-
48
-
49
-
50
-
51
-
52
-
53
-
54
-
55
-
56
-
57
-
58
-
59
-
60
-
61
-
62
-
63
-
64
-
65
-
66
-
67
-
68
-
69
-
70
-
71
-
72
-
73
-
74
-
75
-
76
-
77
-
78
-
79
-
80
-
81
-
82
-
83
-
84
-
85
-
86
-
87
-
88
-
89
-
90
-
91
-
92
-
93
-
94
-
95
-
96
-
97
-
98
-
99
-
100
-
101
-
102
-
103
-
104
-
105
-
106
-
107
-
108
-
109
-
110
-
111
-
112
-
113
-
114
-
115
-
116
-
117
-
118
-
119
-
120
-
121
-
122
-
123
-
124
-
125
-
126
-
127
-
128
-
129
-
130
-
131
-
132
-
133
-
134
-
135
-
136
-
137
-
138
-
139
-
140
-
141
-
142
-
143
-
144
-
145
-
146
-
147
-
148
-
149
-
150
-
151
-
152
-
153
-
154
-
155
-
156
-
157
-
158
-
159
-
160
-
161
-
162
-
163
-
164
-
165
-
166
-
167
-
168
-
169
-
170
-
171
-
172
-
173
-
174
-
175
-
176
-
177
-
178
-
179
-
180
-
181
-
182
-
183
-
184
-
185
-
186
-
187
-
188