HP CP3525dn Service Manual - Page 404
FUSER ERROR, 9 FUSER ERROR, X FUSER ERROR, 20 ERROR, To continue turn off then on, 21 ERROR, 22
UPC - 883585891948
View all HP CP3525dn manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 404 highlights
Table 7-13 Control-panel messages (continued) Control panel message Description Recommended action 50.8 FUSER ERROR The fuser has experienced a lowtemperature error. 1. Remove any paper jams from the fuser area. 2. Reinstall the fuser. Check the connector (J50) between the fuser and the product. Replace the cable or fuser if the connector is damaged. 3. If the problem persists, replace the fuser. See Fuser on page 179. 50.9 FUSER ERROR The fuser has experienced a hightemperature error. 1. Reinstall the fuser. Check the connector (J150) between the fuser and the product. Replace the cable or fuser if the connector is damaged. 2. If the problem persists, replace the fuser. See Fuser on page 179. 50.X FUSER ERROR A fuser error has occurred. Make sure you have the correct fuser. Reseat the fuser. Turn the product off, and then turn the product on. 51.20 ERROR To continue turn off then on The black laser (51.20) or cyan laser (51.21) 1. has experienced an error. Reconnect the connectors of the laser driver PCA (J503) and the DC controller PCA (J111). 51.21 ERROR To continue turn off then on 2. Replace the cyan/black laser scanner. See Laser/scanner assembly (C/Bk) on page 272. 51.22 ERROR To continue turn off then on The magenta laser (51.22) or yellow laser (51.23) has experienced an error. 1. Reconnect the connectors of the laser driver PCA (J501) and the DC controller PCA (J110). 51.23 ERROR To continue turn off then on 2. Replace the yellow/magenta laserscanner. See Laser/scanner assembly (Y/M) on page 265. 51.XY ERROR A printer error has occurred. Turn the product off then on. 51.XY ERROR To continue turn off then on 52.00 ERROR To continue turn off then on The scanner has experienced a startup error. 1. Perform the laser scanner component tests in the DIAGNOSTICS menu. 2. Depending on the test results, perform one of the following steps: ◦ If the cyan or black component tests showed a startup failure, reconnect the connectors (J503) on the laser PCA and (J106 and J111) on DC controller PCA . ◦ If the yellow or magenta component tests showed a startup failure, reconnect the connectors (J501) on the laser PCA and (J106 376 Chapter 7 Solve problems ENWW