HP Integrity Superdome SX2000 HP Integrity Servers with Microsoft Windows Serv - Page 20

HP Smart Update Manager, Installation

Page 20 highlights

Target LUN and boot controller WWN not visible in a VC environment Issue When installing to storage attached to an Emulex LPe1105 mezzanine controller (403621-B21) in a Virtual Connect (VC) environment through a Brocade switch, the target LUN is not visible and the WWN for the boot controller is not visible in the zone in the switch administrative tool. Servers HP Integrity BL860c Server Blade and BL870c Server Blade Workaround Write down and save the controller World-Wide Number (WWN) when installing it into the system, or obtain it from the VC manager or EFI utility. Then, manually enter the WWN into the desired zone on the switch when configuring the zone. Scan for targets and continue with the usual installation steps to boot from the controller. For more information, see the HP StorageWorks Booting Windows for Itanium-based systems from a storage area network document at http://www.hp.com. HP Smart Update Manager hpsum_swdiscovery.exe Application Error Issue Version 3.4.3.0 of the hpsum_swdiscovery.exe tool can cause an Application Error that is reported in the Windows Event Log. Servers All Integrity Workaround 1. Navigate to the C:\CPQSYSTEM\cpxml folder. 2. Remove the cp009280.xml file. 3. Restart SMH. If any pop-up windows display that contain the sw_discovery.exe application name, follow these steps: 1. Navigate to the C:\Program Files\HPWBEM\Tools folder. 2. Replace the hpsum_swdiscovery.exe file with the same file in the Support Pack that you downloaded. Qlogic driver does not install successfully Issue If you have multiple Qlogic cards in your system, HPSUM might not update the driver for some of the cards. Servers All Integrity Workaround Run HPSUM or the particular Qlogic smart component again with force install to update the driver. mmc.exe crash Issue Servers Workaround While running HPSUM, an mmc.exe application crash window might appear. All Integrity Close the window or ignore it. HPSUM continues to run and finishes the installation successfully. Installation Integrity PCI-express power management fix for AH400A/AH401A is always ready to install Issue The Integrity PCI-express power management fix for the AH400A and AH401A HBAs (cp009436.exe) is always "ready to install" even after it is installed. This can occur when running HPSUM interactively from the Smart Setup CD or after you download the Support Pack from the web and run it interactively. 20 Release 6.5 Overview

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

Target LUN and boot controller WWN not visible in a VC environment
Issue
When installing to storage attached to an Emulex LPe1105 mezzanine controller
(403621-B21) in a Virtual Connect (VC) environment through a Brocade switch,
the target LUN is not visible and the WWN for the boot controller is not visible
in the zone in the switch administrative tool.
Servers
HP Integrity BL860c Server Blade and BL870c Server Blade
Workaround
Write down and save the controller World-Wide Number (WWN) when
installing it into the system, or obtain it from the VC manager or EFI utility.
Then, manually enter the WWN into the desired zone on the switch when
configuring the zone. Scan for targets and continue with the usual installation
steps to boot from the controller. For more information, see the
HP StorageWorks
Booting Windows for Itanium-based systems from a storage area network
document
at
http://www
.hp.com
.
HP Smart Update Manager
hpsum_swdiscovery.exe Application Error
Issue
Version 3.4.3.0 of the
hpsum_swdiscovery.exe
tool can cause an Application
Error that is reported in the Windows Event Log.
Servers
All Integrity
Workaround
1.
Navigate to the
C:\CPQSYSTEM\cpxml
folder.
2.
Remove the
cp009280.xml
file.
3.
Restart SMH.
If any pop-up windows display that contain the
sw_discovery.exe
application name, follow these steps:
1.
Navigate to the
C:\Program Files\HPWBEM\Tools
folder.
2.
Replace the
hpsum_swdiscovery.exe
file with the same file in the
Support Pack that you downloaded.
Qlogic driver does not install successfully
Issue
If you have multiple Qlogic cards in your system, HPSUM might not update
the driver for some of the cards.
Servers
All Integrity
Workaround
Run HPSUM or the particular Qlogic smart component again with force install
to update the driver.
mmc.exe crash
Issue
While running HPSUM, an
mmc.exe
application crash window might appear.
Servers
All Integrity
Workaround
Close the window or ignore it. HPSUM continues to run and finishes the
installation successfully.
Installation
Integrity PCI-express power management fix for AH400A/AH401A is always ready to install
Issue
The Integrity PCI-express power management fix for the AH400A and AH401A
HBAs (
cp009436.exe
) is always “ready to install” even after it is installed.
This can occur when running HPSUM interactively from the Smart Setup CD
or after you download the Support Pack from the web and run it interactively.
20