HP LH4r HP Netserver LH Pro User Guide - Page 22
always set to Off.
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Chapter 3 Configuring Mass Storage The switch setting location and functions are the same on both cages. The settings for switch 6 determines upper and lower cage functionality. Switches 1 and 2 are always set to Off. Table 3-1 lists the functional settings for each switch. Table 3-1. Switch Functions and Settings Switch 1 2 3 4 5 6 Function I2C Bus Setting I2C Bus Setting High/Low Addresses Fast-Wide (68 pin) SCSI Only Sets SCSI addresses for upper or lower eight addresses SCSI Address Zero Sets middle shelf in cage to SCSI ID 0. Remote Start Determines control of the hot swap disk module power-on sequence. Upper/Lower Cage Identifies cage location. This is important information for the SCSI addresses and for the I2C bus. Settings Always set to Off Always set to Off On Sets drives to upper eight SCSI addresses. Off Sets drives to lower eight SCSI addresses. See SCSI Address Settings table below for description of settings. On Sets middle shelf in the cage (shelf 2 or shelf 5) to SCSI ID 0. Off Sets middle shelf to normal SCSI address sequence. See Table 3-2 for a description of SCSI address settings. On Internal control: Upper cage is set to delayed start and lower cage is set to power-on at startup. Recommended setting. Off Power-on sequence is determined by the disk array controller. Not supported by HP SCSI controller boards. On Lower cage Off Upper cage See Table 3-2 for a description of SCSI address settings. 16