HP Management LAN Blade for bh7800 Site Preparation Guide, Second Edition - HP - Page 12
System Backplane, DC Power Supplies, Blade Server Backplane, rear view, front view
View all HP Management LAN Blade for bh7800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
HP Carrier Grade Blade Server bh3710 Overview System Backplane System Backplane The passive system backplane is located in the Blade Server to accommodate front and rear blades. Ten Compact PCI slots are located on each side. Figure 1-5 Blade Server Backplane, rear view Figure 1-6 Blade Server Backplane, front view DC Power Supplies Two power supplies and two power cords ship with each system. If dual power supplies will be fed with dual power sources, grounding potentials between the power sources should be measured and verified to be at or near zero volts potential. See "Grounding Systems" for more details. Each power supply comes in two parts: • Power Supply Module (front) • Power Inlet Module (rear) 12 Chapter 1
Chapter 1
HP Carrier Grade Blade Server bh3710 Overview
System Backplane
12
System Backplane
The passive system backplane is located in the Blade Server to accommodate front and rear blades. Ten
Compact PCI slots are located on each side.
Figure 1-5
Blade Server Backplane, rear view
Figure 1-6
Blade Server Backplane, front view
DC Power Supplies
Two power supplies and two power cords ship with each system. If dual power supplies will be fed with dual
power sources, grounding potentials between the power sources should be measured and verified to be at or
near zero volts potential. See “Grounding Systems” for more details.
Each power supply comes in two parts:
•
Power Supply Module (front)
•
Power Inlet Module (rear)