HP Management LAN Blade for bh7800 Site Preparation Guide, Second Edition - HP - Page 37
A System Specifications and Requirements
View all HP Management LAN Blade for bh7800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
A System Specifications and Requirements Table A-1 System Specifications Description Specification Dimensions (H, W, D) 10.5 x 17 x 14 in (26.25 x 42.50 x 35.00 cm) Weight (configured) approximately 51 lbs (23.4 Kg) Input Power Operational: -40 to -70 VDC (Margin included) Recommended: -48 to -60 VDC Temperature Operational: +5 to +35C. (Goal: derate 4C/1000m above 1500m altitude) (Commit: derate 2C/1000m above sea level) Recommended:+20 to +25C Non-Operational: -40 to +70C Humidity Operational: 15% to 80% RH non-condensing @35C Recommended: 40% to 60% RH non-condensing Maximum Altitude Operational: 3000 meters above sea level Non-Operational: 4500 meters above sea level Acoustics Sound Power: 54.0 dBA Bels LwA (not to exceed 7.5 Bels) Figure A-1 Power Supply Label System & Power Supply Input Power -48/ -60 VDC 20/ 16 A Table A-2 Power Consumption (Maximum) Power Required Chassis HP Server bp2200 FC Storage Blade Management Blade Management LAN Blade VAa 0.0 Watts 89.0 Watts 53.1 Watts 18.6 Watts 7.0 Watts System & Power Supply Input Power -48/ -60 VDC 20/ 16 A Appendix A 37