HP P5389A hp server tc3100 operation and maintenance guide (English, v1.1) - Page 62

Serial Port Controller resource, Flexible Disk Drive Cable

Page 62 highlights

Chapter 5 Error Messages Code 0108 0200 0201 0300 0301 0305 Description Mouse and Keyboard connections reversed Serial Port Controller resource conflict Parallel Port Controller resource conflict Flexible disk drive (A) boot error Flexible disk drive B boot error (This does not apply to tc3100) Flexible Disk Drive Cable conflict (This does not apply to tc3100) Problem/Solution POST has detected the mouse and keyboard connections are reversed. To correct this: 1. Turn the server off. 2. Swap the mouse and keyboard connections. 3. Turn on the server power and reboot the server. POST has detected an address space or IRQ resource conflict between one of the integrated serial port controllers and an accessory board. To correct this: 1. If an integrated serial port is not needed, run the Setup Utility and disable the related serial port. 2. If the integrated serial port is needed and its settings cannot be modified, the accessory board's IRQ and address space must be reconfigured to use other free resources. Refer to the accessory board installation manual for information. POST has detected an address space or IRQ resource conflict between the integrated parallel port controller and an accessory board. To correct this: 1. If the integrated parallel port is not needed, run the Setup Utility and disable the parallel port. 2. If the integrated parallel port is needed and its settings cannot be modified, the accessory board's IRQ and address space must be reconfigured to use other free resources. Refer to the accessory board installation manual for information. POST has detected the flexible disk drive (A) reported an error during its self-test. To correct this: 1. Verify a diskette can be properly inserted and removed from the flexible disk drive. 2. Verify the flexible drive type configured in the Setup Utility matches the flexible disk drive installed in the HP Server. 3. Verify all data cables and power cables are firmly connected. 4. If the problem persists, your flexible disk drive may need to be replaced. Contact your service representative. POST has detected the flexible disk drive B reported an error during its self-test. 1. Verify a diskette can be properly inserted and removed from the flexible disk drive. 2. Verify the flexible drive type configured in the Setup Utility matches the flexible disk drive installed in the HP Server. 3. Verify all data cables and power cables are firmly connected. 4. If the problem persists, your flexible disk drive may need to be replaced. Contact your service representative. The flexible disk drive A is connected to the connector configured for flexible disk drive B. 1. Run Setup Utility by pressing F2. In the flexible disk drive section, enable the A & B flexible disk swap. 2. Alternatively, if the connector allows it, connect the flexible disk drive to the other connector on the flexible disk drive cable. 56

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111

Chapter 5
Error Messages
56
Code
Description
Problem/Solution
0108
Mouse and Keyboard
connections reversed
POST has detected the mouse and keyboard connections are reversed.
To correct this:
1. Turn the server off.
2.
Swap the mouse and keyboard connections.
3.
Turn on the server power and reboot the server.
0200
Serial Port Controller resource
conflict
POST has detected an address space or IRQ resource conflict between
one of the integrated serial port controllers and an accessory board.
To correct this:
1.
If an integrated serial port is not needed, run the Setup Utility
and disable the related serial port.
2.
If the integrated serial port is needed and its settings cannot be
modified, the accessory board's IRQ and address space must be
reconfigured to use other free resources. Refer to the accessory
board installation manual for information.
0201
Parallel Port Controller resource
conflict
POST has detected an address space or IRQ resource conflict between
the integrated parallel port controller and an accessory board.
To correct this:
1.
If the integrated parallel port is not needed, run the Setup Utility
and disable the parallel port.
2.
If the integrated parallel port is needed and its settings cannot be
modified, the accessory board's IRQ and address space must be
reconfigured to use other free resources. Refer to the accessory
board installation manual for information.
0300
Flexible disk drive (A) boot
error
POST has detected the flexible disk drive (A) reported an error during
its self-test.
To correct this:
1.
Verify a diskette can be properly inserted and removed from the
flexible disk drive.
2.
Verify the flexible drive type configured in the Setup Utility
matches the flexible disk drive installed in the HP Server.
3.
Verify all data cables and power cables are firmly connected.
4.
If the problem persists, your flexible disk drive may need to be
replaced. Contact your service representative.
0301
Flexible disk drive B boot error
(This does not apply to tc3100)
POST has detected the flexible disk drive B reported an error during
its self-test.
1.
Verify a diskette can be properly inserted and removed from the
flexible disk drive.
2.
Verify the flexible drive type configured in the Setup Utility
matches the flexible disk drive installed in the HP Server.
3.
Verify all data cables and power cables are firmly connected.
4.
If the problem persists, your flexible disk drive may need to be
replaced. Contact your service representative.
0305
Flexible Disk Drive Cable
conflict
(This does not apply to tc3100)
The flexible disk drive A is connected to the connector configured for
flexible disk drive B.
1.
Run Setup Utility by pressing F2. In the flexible disk drive
section, enable the A & B flexible disk swap.
2.
Alternatively, if the connector allows it, connect the flexible disk
drive to the other connector on the flexible disk drive cable.