HP ProLiant DL380 Compaq ProLiant DL380 Generation 2 Server High-Density Deplo - Page 15

Power Cords

Page 15 highlights

Compaq ProLiant DL380 Generation 2 Server High-Density Deployment in Compaq Racks 15 Compaq Confidential - Need to Know Required Power Cords The power cord included with the North American model of the ProLiant DL380 Generation 2 server can be used for low-voltage applications. Use a 1.8-m (6-ft) to 2.4-m (8-ft) long power cord with the standard rack rails and cable management arm. For information on obtaining high-voltage power cords, visit the Compaq website: www.compaq.com Table 8 lists PDU configurations for 42U racks and Table 9 lists PDU configurations for 36U racks. The configurations in these tables refer to racks that are fully populated with servers. Racks fully populated with servers use either an off-rack console management system or a remote console management system. For an example configuration of a rack using an in-rack console management system, see Figure 3. Table 8. PDU Configurations for 42U Racks Part Number 207590-B21 207590-D71 207590-B31 207590-D72 191186-001 191186-B31 197616-B22 295363-001 295363-002 295363-003 295363-291 295363-B21 295363-B32 Input Voltage/ Current Rating Vertical Mount Bracket Kits 166097-B21 191265-B21 with Y-cables High/16 A 2 Low/24 A High/32 A 2 High/30 A 2 High/24 A 2 High/30 A 2 High/32 A 2 Low/24 A 1 High/16 A 2 High/24 A 2 Low 24 A 1 High/16 A 2 High/16 A 2 Maximum Servers 5 3 10 7 7 9 12 3 5 7 3 5 5 PDUs per Rack 4 4 3 3 3 3 2 4 4 3 4 4 4 Populated Rack Weight (lb) 1,813 1,813 1,800 1,800 1,800 1,800 1,787 1,813 1,813 1,800 1,813 1,813 1,813 BTUs 29,400 29,400 29,400 29,400 29,400 29,400 29,400 29,400 29,400 29,400 29,400 29,400 29,400 14UH-0701A-WWEN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Compaq ProLiant DL380 Generation 2 Server High-Density Deployment in Compaq Racks
15
Compaq Confidential - Need to Know Required
14UH-0701A-WWEN
Power Cords
The power cord included with the North American model of the ProLiant DL380
Generation 2 server can be used for low-voltage applications. Use a 1.8-m (6-ft) to 2.4-m (8-ft)
long power cord with the standard rack rails and cable management arm.
For information on obtaining high-voltage power cords, visit the Compaq website:
www.compaq.com
Table 8 lists PDU configurations for 42U racks and Table 9 lists PDU configurations for 36U
racks. The configurations in these tables refer to racks that are fully populated with servers. Racks
fully populated with servers use either an off-rack console management system or a remote
console management system. For an example configuration of a rack using an in-rack console
management system, see Figure 3.
Table 8.
PDU Configurations for 42U Racks
Vertical Mount Bracket Kits
Part Number
Input Voltage/
Current Rating
166097-B21
with Y-cables
191265-B21
Maximum
Servers
PDUs per
Rack
Populated Rack
Weight (lb)
BTUs
207590-B21
High/16 A
2
5
4
1,813
29,400
207590-D71
Low/24 A
3
4
1,813
29,400
207590-B31
High/32 A
2
10
3
1,800
29,400
207590-D72
High/30 A
2
7
3
1,800
29,400
191186-001
High/24 A
2
7
3
1,800
29,400
191186-B31
High/30 A
2
9
3
1,800
29,400
197616-B22
High/32 A
2
12
2
1,787
29,400
295363-001
Low/24 A
1
3
4
1,813
29,400
295363-002
High/16 A
2
5
4
1,813
29,400
295363-003
High/24 A
2
7
3
1,800
29,400
295363-291
Low 24 A
1
3
4
1,813
29,400
295363-B21
High/16 A
2
5
4
1,813
29,400
295363-B32
High/16 A
2
5
4
1,813
29,400