HP Scitex FB10000 Geffen TS Error 67019 - Page 2

Troubleshooting Flowchart, Error ID: 67019: Safety - Front manual loading flap is down

Page 2 highlights

Error ID: 67019: Safety - Front manual loading flap is down Troubleshooting Flowchart Error message (67019) Front manual loading flap is down FB10000 Error Messages Troubleshooting Lift the loading flap and press the blue Yes reset button Is front loading flap physically down ? No Interlock is aligned correctly ? No Realign interlock Replace the X20SI9100 module Check/replace cable (CX161-03540) Yes Check/replace interlock Top Flowchart

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 67019: Safety - Front manual loading flap is down
FB10000 Error Messages Troubleshooting
Troubleshooting Flowchart
Error message
(67019)
Front manual loading flap is down
Is front loading flap
physically down ?
No
Interlock is aligned
correctly ?
Check/replace
interlock
Yes
Realign interlock
No
Replace the
X20SI9100 module
Lift the loading flap
and press the blue
reset button
Yes
Check/replace cable
(CX161-03540)
Top
Flowchart