HP Scitex FB10000 Geffen TS Error 67019 - Page 7

further instructions., If none of the above steps solved the problem

Page 7 highlights

Error ID: 67019: Safety - Front manual loading flap is down FB10000 Error Messages Troubleshooting Top Flowchart 7. Set the Safety PLC selector to 1 (one new module) and press the Enter button to instruct the PLC to configure the new module BU. Upon completion, the MXCHG LED will blink orange once and then will turn off to confirm that the module was configured. Note: This procedure takes up to two minutes. However, when the PLC encounters internal errors, it runs a full system scan and resets the entire system. This procedure takes between 40 to 60 minutes. 8. If the MXCHG LED continues blinking orange once every 5 seconds, this indicates that the PLC failed to configure the new module (in case of 2 replaced modules, it will blink twice every 5 seconds etc.). Check if you have set the scan selector according to the number of new modules. Interchanging two existing modules will be detected by the Safety PLC as two new modules. 9. If the MXCHG LED continues blinking orange once every 5 seconds, please consult the detailed B&R PLC configuration guide, on page 4 for further instructions. 10. If none of the above steps solved the problem, contact your HP service specialist. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 67019: Safety - Front manual loading flap is down
FB10000 Error Messages Troubleshooting
7.
Set the Safety PLC selector to 1 (one new module) and press the Enter button to instruct the PLC to configure the new module BU. Upon
completion, the MXCHG LED will blink orange once and then will turn off to confirm that the module was configured.
Note: This procedure takes up to two minutes. However, when the PLC encounters internal errors, it runs a full system scan and resets
the entire system. This procedure takes between 40 to 60 minutes.
8.
If the MXCHG LED continues blinking orange once every 5 seconds, this indicates that the PLC failed to configure the new module (in case of 2
replaced modules, it will blink twice every 5 seconds etc.). Check if you have set the scan selector according to the number of new modules.
Interchanging two existing modules will be detected by the Safety PLC as two new modules.
9.
If the MXCHG LED continues blinking orange once every 5 seconds, please consult the detailed B&R PLC configuration guide, on page 4 for
further instructions.
10.
If none of the above steps solved the problem, contact your HP service specialist.
Top
Flowchart
3