HP Scitex FB10000 Geffen TS Error 67019 - Page 5

Error ID: 67019: Safety - Front manual loading flap is down, If the results do not correspond

Page 5 highlights

Error ID: 67019: Safety - Front manual loading flap is down FB10000 Error Messages Troubleshooting 7. Check the yellow coaxial cable connecting the interlock receiver to the B&R twice: once with the flap up and once with the flap is down. 8. With the flap is in up position, disconnect the 2SDI2-SI9(14) white wire from the B&R module and the 2TBM-14(3) brown wire from the TBM block and check their continuity. You should get continuity between these two test points. 9. With the flap in down position, disconnect the 2SDI2-SI20(24) (blue) wire from the B&R module and the 2TBM-16(3) (black) wire from the TBM block and check their continuity. You should get continuity between these two test points. 9400 4 500 300 2TBM-14(3) To CX161-03540 5 2SDI2-SI19(14) Rec-Safety Controller Cable INTERLOCK12 3 2TBM-16(3) 30 FRONT UV FLAP 1 CX161-03540 5 Cable INTERLOCK12 FRONT UV FLAP 10 To INTERLOCK12 FRONT UV FLAP 10 2SDI2-SI20(24) 20 Top Flowchart 10. If the results correspond to the above, then we know that the yellow coaxial cable and both parts of the interlock are ok. 11. If the results do not correspond, this might indicate that the interlock receiver is faulty. If this is the case, replace the receiver. 12. If the problem persists after replacing the receiver, this indicates that the safety B&R module X20 SI9100 might be faulty. 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Error ID: 67019: Safety - Front manual loading flap is down
FB10000 Error Messages Troubleshooting
7.
Check the yellow coaxial cable connecting the interlock receiver to the B&R twice: once with the flap up and once with the flap is down.
8.
With the flap is in up position, disconnect the 2SDI2-SI9(14) white wire from the B&R module and the 2TBM-14(3) brown wire from the TBM
block and check their continuity. You should get continuity between these two test points.
9.
With the flap in down position, disconnect the 2SDI2-SI20(24) (blue) wire from the B&R module and the 2TBM-16(3) (black) wire from the TBM
block and check their continuity. You should get continuity between these two test points.
To
Rec-Safety Controller
9400
2TBM-14
(3)
2SDI2-SI19(14)
2TBM-16(3)
500
300
2SDI2-SI20(24)
CX161-03540 5
Cable INTERLOCK12
FRONT UV FLAP
CX161-03540 5
Cable INTERLOCK12
FRONT UV FLAP
3
To
INTERLOCK12
FRONT UV FLAP
1
4
30
10
10
20
10.
If the results correspond to the above, then we know that the yellow coaxial cable and both parts of the interlock are ok.
11.
If the results do not correspond, this might indicate that the interlock receiver is faulty. If this is the case, replace the receiver.
12.
If the problem persists after replacing the receiver, this indicates that the safety B&R module X20 SI9100 might be faulty.