HP StorageWorks 1500cs HP StorageWorks 1500 Modular Smart Array maintenance an - Page 97
Hard drive failures and faulted LUNs, Recognizing hard drive failure, Effects of hard drive
View all HP StorageWorks 1500cs manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
9 Hard drive failures and faulted LUNs The purpose of fault-tolerant array configurations is to protect against data loss due to hard drive failure. Each RAID configuration has inherent limitations on the number of hard drive failures that it can tolerate. If the fault-tolerance level of a particular LUN or array configuration is exceeded, the array will be locked from any further I/O. This protection is designed to preserve the integrity of the local drive, but does require manual intervention to recover or re-enable the LUN. Although controller firmware is designed to protect against normal hard drive failure, it is imperative that you perform the correct actions to recover from a hard drive failure without inadvertently introducing any additional hard drive failures. Included sections: • Recognizing hard drive failure • Compromised fault tolerance • Enabling failed LUNs • Best practices when replacing hard drives • Automatic data recovery Recognizing hard drive failure LEDs on the front of each hard drive are visible from the front of the external storage unit. When a hard drive is configured as a part of an array and attached to a powered-on controller, the status of the hard drive can be determined from the illumination pattern of these LEDs. For detailed descriptions of the various LED combinations, see Hard drive LEDs. Other ways to determine that a hard drive has failed include the following: • LEDs on the storage system chassis illuminate amber if failed hard drives are inside. (However, this LED also illuminates when other problems occur, such as when a fan fails, a redundant power supply fails, or the system overheats.) • LEDs on the hard drives illuminate amber if a hard drive has failed or is a member of a faulted LUN. • Front-panel LCD display messages list faulted LUNs and failed hard drives whenever the system is restarted, as long as the controller detects one or more good hard drives. • ACU represents faulted LUNs and failed drives with distinctive icons. • HP-SIM can detect failed hard drives. • ADU lists all failed hard drives. For more information on troubleshooting hard drive problems, see the HP ProLiant Servers Troubleshooting Guide. Effects of hard drive failure When a hard drive fails, all logical drives that are in the same array are affected. Each logical drive in an array may be using a different fault-tolerance method, so each logical drive can be affected differently. • RAID 0 configurations cannot tolerate hard drive failure. If any physical hard drive in the array fails, all non-fault-tolerant (RAID 0) LUNs in the same array also are failed. • RAID 1 and RAID 1+0 configurations can tolerate multiple hard drive failures, as long as none of the failed hard drives are mirrored to one another. • RAID 5 configurations can tolerate one hard drive failure. maintenance and service guide 97