HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Fabric OS V4.2.x Rele - Page 21
portCfgislMode, HP StorageWorks Fabric OS 4.2.x Procedures User Guide
![]() |
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Documentation Updates Note: portCfgislMode and portCfgLongDistance cannot both be enabled at the same time; otherwise, fabric segmentation occurs. portCfgislMode Add a note regarding coexistence with the portCfgLongDistance command, as follows: Note: portCfgislMode and portCfgLongDistance cannot both be enabled at the same time; otherwise, fabric segmentation occurs HP StorageWorks Fabric OS 4.2.x Procedures User Guide On page 59, add the following note after the paragraph: Domain IDs are assigned dynamically when a switch is enabled. The Domain ID can be set manually; however, to control the number or to resolve a Domain ID conflict when merging fabrics. Note: If a switch already has a Domain ID when enabled, and that Domain ID conflicts with a switch already in the fabric, the conflict is automatically resolved. The resolution can take several seconds, during which traffic is delayed, potentially causing timeouts. HP StorageWorks Management Information Base 4.2.x Reference Guide In Chapter 4, "Entity MIB Objects," remove the entPhysicalContainsTable information on page 132. The correct information appears on page 138. HP StorageWorks Secure Fabric OS 4.2.x User Guide On page 29, after the paragraph: All switches that are shipped with Fabric OS v3.1.2 or v4.2.x ... for information on obtaining digital certificates. Add the following paragraph: SAN Director 2/128 Fabric OS 4.2.x Release Notes 21
![](/manual_guide/products/hewlettpackard-storageworks-2128-hp-storageworks-san-director-2128-fabric-os-v42x-release-notes-352aceb/21.png)